×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Experimental comparison of various techniques for spot size measurement of high-energy X-ray sources

Get Citation
Yi Wang, Qin Li, Nan Chen, Jin-Ming Cheng, Cheng-Gang Li, Hong Li, Quan-Hong Long, Jin-Shui Shi and Jian-Jun Deng. Experimental comparison of various techniques for spot size measurement of high-energy X-ray sources[J]. Chinese Physics C, 2016, 40(8): 086205. doi: 10.1088/1674-1137/40/8/086205
Yi Wang, Qin Li, Nan Chen, Jin-Ming Cheng, Cheng-Gang Li, Hong Li, Quan-Hong Long, Jin-Shui Shi and Jian-Jun Deng. Experimental comparison of various techniques for spot size measurement of high-energy X-ray sources[J]. Chinese Physics C, 2016, 40(8): 086205.  doi: 10.1088/1674-1137/40/8/086205 shu
Milestone
Received: 2015-11-30
Article Metric

Article Views(1801)
PDF Downloads(134)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Experimental comparison of various techniques for spot size measurement of high-energy X-ray sources

    Corresponding author: Yi Wang,
  • 1. Key Laboratory of Pulsed Power, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province, China

Abstract: In flash-radiography experiments, the quality of the acquired image strongly depends on the focal size of the X-ray source spot. A variety of techniques based on imaging of the pinhole, the slit and the rollbar are adopted to measure the focal spot size of the Dragon-I linear induction accelerator. The image of the pinhole provides a two-dimensional distribution of the X-ray spot, while those of the slit and the rollbar give a line-spread distribution and an edge-spread distribution, respectively. The spot size characterized by the full-width at half-maximum and that characterized by the LANL definition are calculated for comparison.

    HTML

Reference (11)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return