×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Investigation of GEM-Micromegas detector on X-ray beam of synchrotron radiation

Get Citation
ZHANG Yu-Lian, QI Hui-Rong, HU Bi-Tao, FAN Sheng-Nan, WANG Bo, LIU Mei, ZHANG Jian, LIU Rong-Guang, CHANG Guang-Cai, LIU Peng, OUYANG Qun, CHEN Yuan-Bo and YI Fu-Ting. Investigation of GEM-Micromegas detector on X-ray beam of synchrotron radiation[J]. Chinese Physics C, 2014, 38(4): 046001. doi: 10.1088/1674-1137/38/4/046001
ZHANG Yu-Lian, QI Hui-Rong, HU Bi-Tao, FAN Sheng-Nan, WANG Bo, LIU Mei, ZHANG Jian, LIU Rong-Guang, CHANG Guang-Cai, LIU Peng, OUYANG Qun, CHEN Yuan-Bo and YI Fu-Ting. Investigation of GEM-Micromegas detector on X-ray beam of synchrotron radiation[J]. Chinese Physics C, 2014, 38(4): 046001.  doi: 10.1088/1674-1137/38/4/046001 shu
Milestone
Received: 2013-05-14
Revised: 2013-06-19
Article Metric

Article Views(1991)
PDF Downloads(251)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Investigation of GEM-Micromegas detector on X-ray beam of synchrotron radiation

    Corresponding author: QI Hui-Rong,

Abstract: To reduce the discharge of the standard bulk Micromegas and GEM detectors, a GEM-Micromegas detector was developed at the Institute of High Energy Physics. Taking into account the advantages of the two detectors, one GEM foil was set as a preamplifier on the mesh of Micromegas in the structure and the GEM preamplification decreased the working voltage of Micromegas to significantly reduce the effect of the discharge. At the same gain, the spark probability of the GEM-Micromegas detector can be reduced to a factor 0.01 compared to the standard Micromegas detector, and an even higher gain could be obtained. This paper describes the performance of the X-ray beam detector that was studied at 1W2B Laboratory of Beijing Synchrotron Radiation Facility. Finally, the result of the energy resolution under various X-ray energies was given in different working gases. This indicates that the GEM-Micromegas detector has an energy response capability in an energy range from 6 keV to 20 keV and it could work better than the standard bulk-Micromegas.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return