Study of n-γ discrimination in low energy range (above 40 keVee) by charge comparison method with a BC501A liquid scintillation detector

Get Citation
CHEN Yong-Hao, CHEN Xi-Meng, ZHANG Xiao-Dong, LEI Jia-Rong, AN Li, SHAO Jian-Xiong, ZHENG Pu, WANG Xin-Hua, ZHU Chuan-Xin, HE Tie and YANG Jian. Study of n-γ discrimination in low energy range (above 40 keVee) by charge comparison method with a BC501A liquid scintillation detector[J]. Chinese Physics C, 2014, 38(3): 036001. doi: 10.1088/1674-1137/38/3/036001
CHEN Yong-Hao, CHEN Xi-Meng, ZHANG Xiao-Dong, LEI Jia-Rong, AN Li, SHAO Jian-Xiong, ZHENG Pu, WANG Xin-Hua, ZHU Chuan-Xin, HE Tie and YANG Jian. Study of n-γ discrimination in low energy range (above 40 keVee) by charge comparison method with a BC501A liquid scintillation detector[J]. Chinese Physics C, 2014, 38(3): 036001.  doi: 10.1088/1674-1137/38/3/036001 shu
Milestone
Received: 2013-03-04
Revised: 1900-01-01
Article Metric

Article Views(1950)
PDF Downloads(358)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Study of n-γ discrimination in low energy range (above 40 keVee) by charge comparison method with a BC501A liquid scintillation detector

    Corresponding author: AN Li,

Abstract: A VME-based experiment system for n-γ discrimination using the charge comparison method was established. A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was developed through the use of LabVIEW. The two-dimensional (2D) scatter plots of the charge in the slow component vs. the total charge from 241Am-Be and 252Cf neutron sources are presented. The 2D scatter plots of the energy vs. the ratio of the charge in the slow component to the total charge of the pulses are also presented. The quality of n-γ discrimination was checked by the figure-of-merit, and the results showed good performance of n-γ discrimination at the low energy range. Neutrons and γ-rays were separated above 50 keVee (electron-equivalent energy). The quality of n-γ discrimination has been improved compared with others' results at five energies (150, 250, 350, 450, 550 keVee).