CDEX-1 1 kg point-contact germanium detector for low mass dark matter searches

Get Citation
KANG Ke-Jun, YUE Qian and WU Yu-Cheng et al. (CDEX collaboration) and (TEXONO collaboration). CDEX-1 1 kg point-contact germanium detector for low mass dark matter searches[J]. Chinese Physics C, 2013, 37(12): 126002. doi: 10.1088/1674-1137/37/12/126002
KANG Ke-Jun, YUE Qian and WU Yu-Cheng et al. (CDEX collaboration) and (TEXONO collaboration). CDEX-1 1 kg point-contact germanium detector for low mass dark matter searches[J]. Chinese Physics C, 2013, 37(12): 126002.  doi: 10.1088/1674-1137/37/12/126002 shu
Milestone
Received: 2013-01-31
Revised: 2013-04-03
Article Metric

Article Views(1946)
PDF Downloads(373)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

CDEX-1 1 kg point-contact germanium detector for low mass dark matter searches

    Corresponding author: YUE Qian,

Abstract: The CDEX collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold point-contact p-type germanium detectors, in China JinPing underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact P+ electrode and the outside N+ electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both P+ and N+ electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments.