Neutron beam monitor based on a boron-coated GEM
- Received Date: 2010-09-15
- Accepted Date: 2011-01-26
- Available Online: 2011-07-05
Abstract: A new thermal neutron beam monitor with a Gas Electron Multiplier (GEM) is developed to meet the needs of the next generation of neutron facilities. A prototype chamber has been constructed with two 100 mm×100 mm GEM foils. Enriched boron-10 is coated on one surface of the aluminum cathode plate as the neutron convertor. 96 channel pads with an area of 8 mm×8 mm each are used for fast signal readout. In order to study the basic characteristics of a boron-coated GEM, several irradiation tests were carried out with α source 239Pu and neutron source 241Am(Be). The signal induced by the neutron source has a high signal-to-noise ratio. A clear image obtained from α source 239Pu is presented, which shows that the neutron beam monitor based on a boron-coated GEM has a good two-dimensional imaging ability.





Abstract
HTML
Reference
Related
PDF












DownLoad: