Present Status of NIRS ECR Ion Sources

Get Citation
M.Muramatsu1, 2, A.Kitagawa2, Y.Iwata2, K.Yamamoto2, H.Ogawa2, S.Hojo2, Y.Sakamoto2,
T.Honma2, W.Takasugi3, M.Wakaisami3, Y.Yoshida4, T.Kubo5, Y.Kato5 and S.Biri6. Present Status of NIRS ECR Ion Sources[J]. Chinese Physics C, 2007, 31(S1): 60-62.
M.Muramatsu1, 2, A.Kitagawa2, Y.Iwata2, K.Yamamoto2, H.Ogawa2, S.Hojo2, Y.Sakamoto2,
T.Honma2, W.Takasugi3, M.Wakaisami3, Y.Yoshida4, T.Kubo5, Y.Kato5 and S.Biri6. Present Status of NIRS ECR Ion Sources[J]. Chinese Physics C, 2007, 31(S1): 60-62. shu
Milestone
Received: 2007-05-30
Revised: 1900-01-01
Article Metric

Article Views(3576)
PDF Downloads(772)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Present Status of NIRS ECR Ion Sources

  • Graduate school of Engineering, Toyo University, Japan2 National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan3 Accelerator Engineering Corporation, Ltd., 2-13-1 Konakadai, Inage, Chiba 263-0043, Japan4 Department of Mechanical Engineering, Toyo University, 2100 Kujirai, Kawagoe, Saitama 350-0815, Japan5 Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan6 Institute of Nuclear Research ATOMKI, H-4026 Debrecen, Ben ter 18/c, Hungary7 K.V.I., University of Groningen, Zernikelaan 25, 9747AA Groningen, Netherlands

Abstract: Four ECR ion sources have been operated in National Institute of Radiological Sciences (NIRS). Two ECR ion sources supply various ion species for the Heavy Ion Medical Accelerator in Chiba (HIMAC). The 10GHz NIRS-ECR ion source mainly produces C2+ ions for the heavy-ion therapy. Ions of Si, Ar, Fe, Kr and Xe are usually produced by the 18GHz NIRS-HEC ion source for physical and biological experiments. The other two compact ECR ion sources with all permanent magnet configuration have been developed for the new generation carbon therapy facility. One of these, the Kei-source, is a prototype which has been installed to the NIRS-930 cyclotron for axial injection. The other source, Kei2-source, is a demonstration source and utilized for the new generation Linac. In addition, both Kei sources have been used to study fundamental properties. In this paper, present status of the ion sources and recent developments are reported.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return