×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Calibration of Soft X-Ray Detection with Synchrotron Radiation

  • In this paper the calibrations of different soft X-ray detector elements used in experiment diagnostics of Inertial Confinement Fusion (ICF) with Synchrotron Radiation is reported. Beijing Synchrotron Radiation Facility used special operation type with beam current 35—110mA, the storage ring electron energy 2GeV, photon energy region 50—1500eV. The performance of the light source is studied by transmission grating and face array CCD system. We divide 50—1500eV energy region in seven energy section through different material prefilter with monochromaticity than 95%. The energy response of different soft X-ray detector elements are calibrated. The calibration results are used in ICF data analysis, which secures the accuracy of data treatment.
  • 加载中
  • [1] .YU Min.Look into the Inertial Confinemente Fusion,China Academe ofEngineering Physcis,CAEP —001,HL~0001,19882.CHANG Tie2Qiang et al.High Power Laser and Particle Beams,1989,1(3):193 —209 (in Chinese)(常铁强等.强激光与粒子束,1989,1(3):193 —209)3.QI Lan2Ying et al.High Power Laser and Particle Beams,1991,3 (4):503 —511 (in Chinese)(祁兰英等.强激光与粒子束,1991,3(4):503 —511)4.CUI Min2Qi et al.High Energy Physics and Nuclear Physics,1992,16 (8):673 —678 (in Chinese)(崔明启等.高能物理与核物理,1992,16 (8):673 —678)5.CUI Min2Qi et al.High Energy Physics and Nuclear Physics,1995,19 (1):82 —86 (in Chinese)(崔明启等.高能物理与核物理,1995,19 (1):82 —86)6.SUN Ke2Xu et al.ACTA PHYSICA,1997,46 (4):650 —655 (in Chi2nese)(孙可煦等.物理学报,1997,46 (4):650 —655)7.SUN Ke2Xu et al.High Energy Physics and Nuclear Physics,2001,25(5):448 —454 (in Chinese)(孙可煦等.高能物理与核物理,2001,25(5):448 —454)8.CUI Cong2Wu et al.High Energy Physics and Nuclear Physics,1998,22(2):180 —184 (in Chinese)(崔聪悟等.高能物理与核物理,1998,22(2):180 —184)9.Henke B L,Smith J A,Attwood D T.J.App.Phys.,1977,48 (5):185210.Henke B L,Knauer J P,remaratne K P.J.Appl.Phys.,1981,52 (3):150911.Saloman E B.Nuclear Instruments and Methods,1980,172:79 —87
  • 加载中

Get Citation
SUN Ke-Xu, YI Rong-Qing, JIANG Shao-En, YANG Jia-Min, HUANG Tian-Xuan, CUI Yan-Li, YANG Guo-Hong, DING Yong-Kun, LIU Shen-Ye, ZhANG Bao-Han, WANG Hong-Bin, WEN Shu-Huai, Calibration of Soft X-Ray Detection with Synchrotron Radiation[J]. Chinese Physics C, 2004, 28(2): 205-209.
SUN Ke-Xu, YI Rong-Qing, JIANG Shao-En, YANG Jia-Min, HUANG Tian-Xuan, CUI Yan-Li, YANG Guo-Hong, DING Yong-Kun, LIU Shen-Ye, ZhANG Bao-Han, WANG Hong-Bin, WEN Shu-Huai, Calibration of Soft X-Ray Detection with Synchrotron Radiation[J]. Chinese Physics C, 2004, 28(2): 205-209. shu
Milestone
Received: 2003-03-17
Revised: 1900-01-01
Article Metric

Article Views(3206)
PDF Downloads(668)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Calibration of Soft X-Ray Detection with Synchrotron Radiation

    Corresponding author: YI Rong-Qing,
  • National Key Laboratory of Laser Fusion,Research Center of Laser Fusion,CAEP,Mianyang 621900,China2 SR Laboratory of Institute of High Energy Physics,CAS,Beijing 100039,China

Abstract: In this paper the calibrations of different soft X-ray detector elements used in experiment diagnostics of Inertial Confinement Fusion (ICF) with Synchrotron Radiation is reported. Beijing Synchrotron Radiation Facility used special operation type with beam current 35—110mA, the storage ring electron energy 2GeV, photon energy region 50—1500eV. The performance of the light source is studied by transmission grating and face array CCD system. We divide 50—1500eV energy region in seven energy section through different material prefilter with monochromaticity than 95%. The energy response of different soft X-ray detector elements are calibrated. The calibration results are used in ICF data analysis, which secures the accuracy of data treatment.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return