×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Monte-Carlo Investigation on the Performance of Huairou EAS Array

Get Citation
Luo Guangxuan, Tan Youheng, Zhang Chunsheng, Dong Yuju, Yuan Peng, Zhang Huimin, Wang Hui, Yuan Yukui and Li Jing. Monte-Carlo Investigation on the Performance of Huairou EAS Array[J]. Chinese Physics C, 1995, 19(10): 884-890.
Luo Guangxuan, Tan Youheng, Zhang Chunsheng, Dong Yuju, Yuan Peng, Zhang Huimin, Wang Hui, Yuan Yukui and Li Jing. Monte-Carlo Investigation on the Performance of Huairou EAS Array[J]. Chinese Physics C, 1995, 19(10): 884-890. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(3201)
PDF Downloads(504)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Monte-Carlo Investigation on the Performance of Huairou EAS Array

    Corresponding author: Luo Guangxuan,
  • Institute of High Energy Physics, The Chinese Academy of Sciences,Beijing 100039

Abstract: 360 thousands of Monte-Carlo EAS events have been simulated by using the "GENAS" package as well as the geometry and instrument response of Huairou EAS array.They are used for the investigation of array perfromance and event selection criteria,and for the check of experimental data.It shows that there are fair coincidence between the experimental and the simulated results on the trigger rate, the zenith angle distribution, the Size response etc.The accuracies of core position and arrival direction are about 3m and 2.5°, respectively.The relative error of EAS Size determination is about 8% when the Size is about 106,the peak value of energy response of array is 5×1014ev and the best fit of the relation between EAS Size and primary energy is E≈10.64N0.84.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return