A Two-Dimensional Position Sensitive Multi-Stage Detection System with a Wide Dynamic Range for Heavy Ion Reaction

Get Citation
Wang Jinchuan, Zhan Wenlong, Guo Zhongyan, Xi Hongfei, Zhou Jianqun, Zhao Youxiong, Lei Huaihong and Luo Yongfeng. A Two-Dimensional Position Sensitive Multi-Stage Detection System with a Wide Dynamic Range for Heavy Ion Reaction[J]. Chinese Physics C, 1996, 20(S1): 23-29.
Wang Jinchuan, Zhan Wenlong, Guo Zhongyan, Xi Hongfei, Zhou Jianqun, Zhao Youxiong, Lei Huaihong and Luo Yongfeng. A Two-Dimensional Position Sensitive Multi-Stage Detection System with a Wide Dynamic Range for Heavy Ion Reaction[J]. Chinese Physics C, 1996, 20(S1): 23-29. shu
Milestone
Received: 1995-03-15
Fund

    Supported by the National Natural Science Foundation of China and the Science Foundation of the Chinese Academy of Sciences.

Article Metric

Article Views(534)
PDF Downloads(4)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

A Two-Dimensional Position Sensitive Multi-Stage Detection System with a Wide Dynamic Range for Heavy Ion Reaction

  • Institute of Modem Physics, The Chinese Academy of Sciences, Lanzhou, China
Fund Project:  Supported by the National Natural Science Foundation of China and the Science Foundation of the Chinese Academy of Sciences.

Abstract: A two-dimensional position sensitive multi-stage detection system with a wide dynamic range for a heavy ion reaction is described in this paper. It consists of four parts:a longitudinal electric field gas filled Ionization Chamber (IC), a Position Sensitive Silicon Detector (PSSD) (45 mm×45 mm, 400 μm), a large area PIN Silicon Photodiode (SPD) (48 mm×48 mm, 300 μm),and a 16 element CsI(Tl) scintillation detector array. The energy resolutions for IC and PSSD tested with a source 241Am(5.486 MeV) are 3% and 2.6%, respectively. The energy dynamic range for α particle detection is about 2-130 MeV, and the fragments with Z Values from Z=2 to Z=21 are identified in the reaction of 25 MeV/u 40Ar+ 115In. The Z resolving power is Z/△Z ≈ 44.5 (FWHM) for Z=18. The position resolution of PSSD is 0.86±0.03 mm (FWHM).

    HTML

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return