×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Get Citation
WANG DIAN-RONG, WANG XIAN-PEI, LIN JIAN-FENG, JIANG YING-YUAN, XI JI-WEI, XIE YI-GANG, XU YU-LIN, LI CHENG-ZE, CHEN YUAN-BAI, CHEN ZHI-PING and HAN SHU-RONG. SCINTILLATION COUNTER ARRAY LOCALIZATION SYSTEM[J]. Chinese Physics C, 1981, 5(5): 569-575.
WANG DIAN-RONG, WANG XIAN-PEI, LIN JIAN-FENG, JIANG YING-YUAN, XI JI-WEI, XIE YI-GANG, XU YU-LIN, LI CHENG-ZE, CHEN YUAN-BAI, CHEN ZHI-PING and HAN SHU-RONG. SCINTILLATION COUNTER ARRAY LOCALIZATION SYSTEM[J]. Chinese Physics C, 1981, 5(5): 569-575. shu
Milestone
Received: 1981-03-18
Revised: 1900-01-01
Article Metric

Article Views(2338)
PDF Downloads(246)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

SCINTILLATION COUNTER ARRAY LOCALIZATION SYSTEM

Abstract: A scintillation counter array localization system, i.e, scintillation counter hodoscope, was studied and made for selecting events and triggering the streamer chamber in 1980. With this facility the penetrating position of the charged particles can be determined and it can be used as a trigger counter too. As soon as the charged particles penetrated this array and other scintillation telescope, the generated coincidence signal triggers the control system of the streamer chamber with the time delay 74 ns.On the other hand, this system also has a ability of selecting charged particle number penetrating the counter array, thus, the streamer chamber is able to record the event with certain multiplicity.This hodoscope contains a 8×8 scintillation counter array. Each plastic scintillator (type ST401) has the dimensions of 40×5×0.6 cm3 and the type of photomultipliers used is GDB50. The array area is 40×40 cm2.The fast electronics and data handling system were made by ourselves. The whole system works well during the test with the on-line microcomputer TRS-80 and is not expensive.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return