Preparation of 182Hf AMS Standard Sample and Test on HI-13 Tandem AMS

Get Citation
YIN Xin-Yi, HE Ming, DONG Ke-Jun, QIU Jiu-Zi, WU Shao-Yong, ZHANG Jin-Song, ZHANG Chun-Hua, ZHENG Yun, GUAN Yong-Jing and JIANG Shan. Preparation of 182Hf AMS Standard Sample and Test on HI-13 Tandem AMS[J]. Chinese Physics C, 2007, 31(10): 978-981.
YIN Xin-Yi, HE Ming, DONG Ke-Jun, QIU Jiu-Zi, WU Shao-Yong, ZHANG Jin-Song, ZHANG Chun-Hua, ZHENG Yun, GUAN Yong-Jing and JIANG Shan. Preparation of 182Hf AMS Standard Sample and Test on HI-13 Tandem AMS[J]. Chinese Physics C, 2007, 31(10): 978-981. shu
Milestone
Received: 2006-11-28
Revised: 2007-03-19
Article Metric

Article Views(3584)
PDF Downloads(582)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Preparation of 182Hf AMS Standard Sample and Test on HI-13 Tandem AMS

    Corresponding author: YIN Xin-Yi,
  • Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, China2 Nuclear Power Institute of China, Sichuan, Jiajiang 610005, China

Abstract: The preparation and accelerator mass spectrometry (AMS) measurements of a series of 182Hf AMS calibration standards are described in this paper. The preparation consists of five processes, the synthesis of the initial 182Hf/180Hf standard sample by double neutron capture reaction of 180Hf, the accurate measurement of this standard for isotopic ratio with thermal ionization mass spectrometry (TIMS), the chemical separation of isobaric interference 182W, the sequential dilution of the initial standard, and the preparation of HfF4. The value of 182Hf/180Hf in the initial 182Hf/180Hf standard was obtained with TIMS to be (1.63±0.01)×10-6. Chemical separation and purification procedures were developed and applied in the preparation of all 182Hf/180Hf standards for the removal of major isobaric interference nuclide 182W. As a result, three 182Hf AMS standards with 182Hf/180Hf ratios of (1.63±0.01)×10-6, (3.22±0.26)×10-8, (3.45±0.32)×10-10 were obtained. AMS measurements of these standard samples were performed and good linearity was obtained in a plot of AMS results vs nominal values for 182Hf/180Hf ranging from 1.63×10-6 to 3.45×10-10.

    HTML

Reference (1)