A PIN Pulse Neutron Detector of Insensitive to Gamma

Get Citation
YANG Hong-Qiong, ZHU Xue-Bin, PENG Tai-Ping, TANG Zheng-Yuan, YANG Gao-Zhao, LI Lin-Bo, SONG Xian-Cai and HU Meng-Chun. A PIN Pulse Neutron Detector of Insensitive to Gamma[J]. Chinese Physics C, 2004, 28(7): 744-748.
YANG Hong-Qiong, ZHU Xue-Bin, PENG Tai-Ping, TANG Zheng-Yuan, YANG Gao-Zhao, LI Lin-Bo, SONG Xian-Cai and HU Meng-Chun. A PIN Pulse Neutron Detector of Insensitive to Gamma[J]. Chinese Physics C, 2004, 28(7): 744-748. shu
Milestone
Received: 2003-11-11
Revised: 1900-01-01
Article Metric

Article Views(2840)
PDF Downloads(522)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

A PIN Pulse Neutron Detector of Insensitive to Gamma

    Corresponding author: YANG Hong-Qiong,
  • Institute of Nuclear Physics and Chemistry,China Academy of Engineering Physics,Mianyang 621900,China2 Institute of Electronic Engineering,China Academy of Engineering Physics,Mianyang 621900,China

Abstract: A new type combination PIN detector was developed and studied using γ and 14MeV neutron radiations generated by Dense Plasma Focus device. The study shows that the detector is insensitive to γ radiation, and the sensitivity to neutron depends on the converter target of neutron radiation. The signal to noise of the detector is 30∶1, it is a new type pulse neutron detector in the neutron and γ mixture radiations.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return