Development of an Intermediate Energy Heavy-Ion Micro-Beam Irradiation System

  • The micro-beam irradiation system, which focuses the beam down to micron order and precisely delivers a predefined number of ions to a predefined spot of micron order, is a powerful tool for radio-biology, radio-biomedicine and micromachining. The Institute of Modern Physics of Chinese Academy of Sciences is developing a heavy-ion micro-beam irradiation system up to intermediate energy. Based on the intermediate and low energy beam provided by Heavy Ion Research Facility of Lanzhou, the micro-beam system takes the form of the magnetic focusing. The heavy-ion beam is conducted to the basement by a symmetrical achromatic system consisting of two vertical bending magnets and a quadrupole in between. Then a beam spot of micron order is formed by a magnetic triplet quadrupole of very high
    gradient. The sample can be irradiated either in vacuum or in the air. This system will be the first opening platform capable of providing heavy ion micro-beam, ranging from low (10MeV/u) to intermediate energy (100MeV/u), for irradiation experiment with positioning and counting accuracy. Target material may be biology cell, tissue or other non-biological materials. It will be a help for unveiling the essence of heavy-ion interaction with matter and also a new means for exploring the application of heavy-ion irradiation.
  • 加载中
  • [1] . Legge G J F. A History of Ion Microbeams. Nucl. Instrum. Methods, 1997, B130: 9-192. Folkard M, Vojnovic B, Prise K M et al. The Application of Charged-Particle Microbeams in Radiobiology. Nucl. Instrum. Methods, 2002, B188: 49-543. Randers-Pehrson G, Geard C R, Johnson G et al. The Columbia University Single-Ion Microbeam. Radiation Research, 2001, 156: 210-2144. Fischer B E, Heib M, Cholewa M. About the Art to Shoot with Single Ions. Nucl. Instrum. Methods, 2003, B210:285-2915. Metzger S, Fischer B E. Locating Radiation Sensitive Zones of Integrated Circuits Using an Ion-Microprobe. Microelectronic Engineering, 1996, 31: 41-46
  • 加载中

Get Citation
SONG Ming-Tao, SHENG Li-Na, WANG Zhi-Guang, HE Yuan, GAO Da-Qing, YANG Xiao-Tian, LIU Jie, SU Hong and MAN Kai-Di. Development of an Intermediate Energy Heavy-Ion Micro-Beam Irradiation System[J]. Chinese Physics C, 2008, 32(S1): 259-261.
SONG Ming-Tao, SHENG Li-Na, WANG Zhi-Guang, HE Yuan, GAO Da-Qing, YANG Xiao-Tian, LIU Jie, SU Hong and MAN Kai-Di. Development of an Intermediate Energy Heavy-Ion Micro-Beam Irradiation System[J]. Chinese Physics C, 2008, 32(S1): 259-261. shu
Milestone
Received: 2008-01-11
Revised: 1900-01-01
Article Metric

Article Views(4069)
PDF Downloads(974)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Development of an Intermediate Energy Heavy-Ion Micro-Beam Irradiation System

    Corresponding author: SONG Ming-Tao,

Abstract: The micro-beam irradiation system, which focuses the beam down to micron order and precisely delivers a predefined number of ions to a predefined spot of micron order, is a powerful tool for radio-biology, radio-biomedicine and micromachining. The Institute of Modern Physics of Chinese Academy of Sciences is developing a heavy-ion micro-beam irradiation system up to intermediate energy. Based on the intermediate and low energy beam provided by Heavy Ion Research Facility of Lanzhou, the micro-beam system takes the form of the magnetic focusing. The heavy-ion beam is conducted to the basement by a symmetrical achromatic system consisting of two vertical bending magnets and a quadrupole in between. Then a beam spot of micron order is formed by a magnetic triplet quadrupole of very high
gradient. The sample can be irradiated either in vacuum or in the air. This system will be the first opening platform capable of providing heavy ion micro-beam, ranging from low (10MeV/u) to intermediate energy (100MeV/u), for irradiation experiment with positioning and counting accuracy. Target material may be biology cell, tissue or other non-biological materials. It will be a help for unveiling the essence of heavy-ion interaction with matter and also a new means for exploring the application of heavy-ion irradiation.