Analytical and simulation studies for diode and triode ion beam extraction systems

Get Citation
M. M. Abdelrahman, N. I. Basal and S. G. Zakhary. Analytical and simulation studies for diode and triode ion beam extraction systems[J]. Chinese Physics C, 2012, 36(4): 344-349. doi: 10.1088/1674-1137/36/4/009
M. M. Abdelrahman, N. I. Basal and S. G. Zakhary. Analytical and simulation studies for diode and triode ion beam extraction systems[J]. Chinese Physics C, 2012, 36(4): 344-349.  doi: 10.1088/1674-1137/36/4/009 shu
Milestone
Received: 2011-06-27
Revised: 2011-07-25
Article Metric

Article Views(1913)
PDF Downloads(412)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Analytical and simulation studies for diode and triode ion beam extraction systems

Abstract: This work is concerned with ion beam dynamics and compares the emittance to aberration ratios of two-and three-electrode extraction systems. The study is conducted with the aid of Version 7 of SIMION 3D ray-tracing software. The beam dependence on various parameters of the extraction systems is studied and the numerical results lead to qualitative conclusions.
Ion beam characteristics using diode and triode extraction systems are investigated with the aid of the computer code SIMION 3 D, Version 7.0. The diode (two electrode extraction system) and triode (three-electrode extraction, acceleration-deceleration system) extraction systems are designed and optimized with di erent geometric parameters of the electrode system, voltage applied to the extraction electrode, and plasma parameters inside the ion source chamber, as well as by the ion beam space charge. This work attempts to describe the importance of the acceleration-deceleration extraction system. It shows that besides an increase of the beam energy, the ion beam has lower emittance than the two-electrode extraction system. Ion beams of the highest quality are extracted whenever the half-angular divergence is minimum for which the perveance current intensity and the extraction gap have optimum value. Knowing the electron temperature of the plasma is necessary to determine plasma potential and the exact beam energy.