Preliminary shielding analysis in support of the CSNS target station shutter neutron beam stop design

Get Citation
ZHANG Bin, CHEN Yi-Xue, WANG Wei-Jin, YANG Shou-Hai, WU Jun, YIN Wen, LIANG Tian-Jiao and JIA Xue-Jun. Preliminary shielding analysis in support of the CSNS target station shutter neutron beam stop design[J]. Chinese Physics C, 2011, 35(8): 791-795. doi: 10.1088/1674-1137/35/8/017
ZHANG Bin, CHEN Yi-Xue, WANG Wei-Jin, YANG Shou-Hai, WU Jun, YIN Wen, LIANG Tian-Jiao and JIA Xue-Jun. Preliminary shielding analysis in support of the CSNS target station shutter neutron beam stop design[J]. Chinese Physics C, 2011, 35(8): 791-795.  doi: 10.1088/1674-1137/35/8/017 shu
Milestone
Received: 2010-10-08
Revised: 1900-01-01
Article Metric

Article Views(2427)
PDF Downloads(545)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Preliminary shielding analysis in support of the CSNS target station shutter neutron beam stop design

Abstract: The construction of China Spallation Neutron Source (CSNS) has been initiated in Dongguan, Guangdong, China. Thus a detailed radiation transport analysis of the shutter neutron beam stop is of vital importance. The analyses are performed using the coupled Monte Carlo and multi-dimensional discrete ordinates method. The target of calculations is to optimize the neutron beamline shielding design to guarantee personal safety and minimize cost. Successful elimination of the primary ray effects via the two-dimensional uncollided flux and the first collision source methodology is also illustrated. Two-dimensional dose distribution is calculated. The dose at the end of the neutron beam line is less than 2.5 μSv/h. The models have ensured that the doses received by the hall staff members are below the standard limit required.