-
Abstract:
A new gamma-ray detecting device called ICI detector has been developed and tested. Like vacuum Compton diode(VCD) and dielectric Compton diode(DCD) generally used in pulsed gamma-ray measurements, ICI detector operates by utilization of the Compton effect and has low sensitivity to gamma-ray fluxes, very fast time response, large linearity and wide dynamic range, it is desired for using the device to measure intense and rapidly changing gamma-ray fluxes. Compared to the existing VCDs and DCDs, the detector requires no vacuum in operation and the active volume is only 2mm thick.
-
-
References
[1]
|
. LIU Zhao-Qing et al. Pulse radiation Measurement. Bei-jing: Science Press, 1994. 186-196(in Chinese)(刘兆庆等.脉冲辐射场诊断技术.北京:科学出版社,1994.186-196)2. NI Yuan-Xing. Pulse Radiation Measurement and Diagno-sis. Xi'an: Northwest Institute of Nuclear Technology, 1997.64-77(in Chinese)(倪源兴.脉冲射线测量和诊断技术.西安:西北核技术研究所1997. 64-77)3. Ebert P J, Lauzon A F. Vacuum Diode Detector for Measuring High Intensity Gamma-Ray Flux. Rev. Sci. Instr.,1967, 38(12): 1747-7524. Fewell T R. Compton Diodes: Theory and Development for Radiation Detectors: SC-DR-720118. 19725. Knoll G F. Radition Detection and Measurement [M]. New York: John Wiley Sons, Inc., 20006. Stevens J. Design and Characterization of an Absolute Gamma-Ray Intensity Detection: EGG1183-2288. 19727. Artuso J, Stevens J. Linearity, Time Domain Reflector Me-ter and Fourier Analysis Studies of an Evacuated Compton Detector: EGG 1183?277. 19718. Ebert P J, Lauzon A F. IEEE Trans. Nucl. Sci., 1966, NS-13(2): 735-7419. Briesmeister J B. MCNP-A General Monte Carlo N-Particle Transport code: LA-12625-M-Manual. 199710. OUYANG X P, LI Z F, WANG Q S et al. HEP NP, 2005,29(4): 399-403(in Chinese)(欧阳晓平,李真富,王群书等.高能物理与核物理,2005,29(4): 399-403)11. OUYANG X P, LI Z F, HUO Y K et al. HEP NP, 2001,25(11): 1100-1105(in Chinese)(欧阳晓平,李真富,霍裕昆等.高能物理与核物理,2001,25(11): 1100-1105)12. OUYANG X P, LI Z F, WANG Q S et al. Acta Physica Sinica, 2005, 54(10): 4643-6647(in Chinese)(欧阳晓平,李真富,王群书等.物理学报,2005, 54(10):4643-4647)
|
-
[1] |
HU Xi-Duo
, SHAO Ming-Zhu
, LUO Shi-Yu
, LIU Yong-Sheng
, ZHU De-Hai
. Average Field Idea and Single Particle Model for 2 Dimension Crystallization Beams(Ⅱ). Chinese Physics C,
2004, 28(2): 196-199. |
[2] |
PENG Quan-Ling
, SUN Jian
, ZHAO Guang-Yuan
, SHI Cai-Tu
. Principle and Software Design of Helmhotz Coil Measurement System. Chinese Physics C,
2001, 25(9): 920-925. |
[3] |
WANG Man
, LI Jin
, CUI Xiang-Zong
, XIA Xiao-Mi
, LAI Yuan-Fen
, YAO Xiao-Guang
. PROTOTYPE OF END CAP SHOWER COUNTERAND ITS BEAM TEST. Chinese Physics C,
1987, 11(3): 321-326. |
-
Access
-
-