The primary physics objective of the Jiangmen Underground Neutrino Observatory (JUNO) is to determine the neutrino mass ordering and measure neutrino oscillation parameters with high precision by detecting reactor antineutrinos through the inverse beta decay reaction (IBD) [1, 2, 3]. In addition, JUNO can study neutrinos from various astrophysical sources, including the Sun, core-collapse supernovae, and the Earth. To achieve these physics goals, the detector's intrinsic background must be sufficiently low. This background is dominated by the natural radioactivity of detector materials and cosmic-ray-induced backgrounds. The JUNO detector is constructed at a depth of about 650 m, which reduces the cosmic-ray component to a sufficiently low level. However, controlling the natural radioactive content of detector materials remains critical throughout detector design, production, and installation, requiring meticulous quality control based on dedicated radioactivity measurements. To meet JUNO's sensitivity requirement for determining the neutrino mass ordering, the background count rate, or singles rate, originating from natural radioactivity must be kept below 10 Hz [1]. This requirement also ensures the target sensitivity for supernova neutrino detection, which is also based on IBD analysis. For solar neutrino studies, however, intrinsic radioactivity dominates the background, and the requirements for LS radiopurity are more stringent and depend strongly on the contaminant type [4, 5, 6].
JUNO is the world's largest liquid scintillator (LS) detector to date; a schematic diagram of its design is shown in Figure 1, and details can be found in Ref. [2]. Twenty thousand tons of LS are contained within an acrylic sphere with an inner diameter of 35.4 m and a wall thickness of 0.12 m. The 600-ton acrylic vessel is constructed on site by assembling 263 acrylic panels layer by layer. The entire acrylic sphere is supported by an outer stainless steel (SS) structure with a diameter of 41.1 m, connected via SS support rods. The outer surface of the sphere features 590 acrylic nodes for attaching these SS support rods. The central detector (CD) consists of the acrylic vessel and the SS structure. The space outside the acrylic sphere is filled with 40,000 tons of ultrapure water, which shields against backgrounds from the surrounding rock and serves as a water Cherenkov detector (WCD).
To capture the faint light signals from neutrino interactions, 17,596 20-inch photomultiplier tubes (PMTs) and 25,587 3-inch PMTs are installed on the inner side of the SS truss. In addition, 2,399 20-inch PMTs are installed on the outer side of the SS truss to observe cosmic rays [7]. To minimize interference from long cables, the readout electronics and high-voltage modules for the PMTs are located underwater, directly adjacent to the PMTs. This arrangement requires extremely high waterproofing standards.
Magnetic shielding coils installed outside the SS truss are used to mitigate the effects of the Earth's magnetic field on the PMTs. A plastic scintillator tracker installed at the top of the detector assists the water Cherenkov detector in tagging cosmic rays. Because the LS inside the acrylic sphere and the water outside have different densities, the liquid level inside the sphere must be higher than that outside. To accommodate this requirement, a 9-m-high chimney is installed above the acrylic sphere and connects it to the calibration room at the top. This chimney serves two purposes: it allows for LS overflow caused by temperature-induced volume changes, and it facilitates the deployment of calibration sources into the detector for energy response measurements.
The energy calibration is performed using a redundant system of multiple sources, both radioactive and laser-based, and multidimensional scanning systems [8]. For a one-dimensional scan, the Automatic Calibration Unit (ACU) can deploy sources along the central axis of the detector. Off-axis calibration positions are obtained using a Cable Loop System (CLS), which can be moved within a vertical half-plane by adjusting the lengths of two connection cables. During CLS calibration, the source position can be verified using four high-resolution Charge-Coupled Device (CCD) cameras (6576×4384) mounted on the equator. These cameras locate an active light source suspended beneath the calibration source, thereby determining the source position. A Guide Tube Calibration System (GTCS) surrounds the exterior of the acrylic sphere and runs in a longitudinal loop to calibrate the nonuniformity of the energy response at the detector boundary. A source is pulled into the Teflon GTCS with servomotors to reach the desired locations. For both the CLS and GTCS, an array of eight customized low-radioactivity Ultrasonic Sensor System (USS) receivers enables reconstruction of source positions based on signals emitted by transmitters on the source attachment fixture.
The spontaneous decay of naturally occurring radioactive nuclides in detector materials emits radiation, including α, β, and γ rays, which can enter the LS and contribute to the background of neutrino events. Charged particles such as α and β emitted by materials outside the LS are strongly attenuated and rarely reach the LS, whereas neutral γ rays can penetrate into the LS and contribute to the background. As γ rays propagate through matter, their energies are progressively attenuated; therefore, stricter radioactivity control is required for materials located closer to the LS than for those farther away. Based on the JUNO software framework, we simulated natural radioactivity on the outer surface of the acrylic sphere, PMTs, and SS truss [9]. The radioactivity contributions from the PMTs and SS truss are approximately three orders of magnitude lower than that from the acrylic outer surface because of the presence of about 3 m of water shielding. The requirements for the concentrations of naturally occurring radioactive nuclides inside the LS are particularly stringent, because all decay products can deposit energy in the LS and contribute directly to the background. Based on a combination of industry-wide production capacity surveys and simulation studies, the design specifications for radioactive impurity levels in various detector materials have been defined, and the resulting event rates in the LS are summarized in Table 1 [9]. The table shows the target impurity concentrations for 238U, 232Th, 40K, 210Pb, and 60Co. The simulation assumes that the uranium and thorium decay chains are in secular equilibrium. In the first row, LS-reactor refers to the minimum radiopurity requirements for the LS to accomplish the primary physics objectives of JUNO using reactor antineutrinos. The simulated event rates reported in the last two columns of the table correspond, respectively, to the entire detector volume (DV) and to a fiducial volume (FV) with radius R < 17.2 m, for energies above 0.7 MeV. In the table, rows for the same material are subcategorized into separate entries. This accounts for contributions from materials deployed at various locations and from different types of PMTs. Even for the same material type, the background contribution can vary depending on the installation position. The background levels of products manufactured by different PMT manufacturers vary significantly; therefore, these are listed in distinct rows. In the "Other" row, several minor contributors are grouped together. These include calibration components and cables installed on the inner surface of the acrylic sphere (0.12 Hz), water from the Cherenkov detector (0.06 Hz), and the rock wall (0.13 Hz). Notably, the water in the WCD is required to have a U/Th content better than 10−14 g/g, a 222Rn concentration better than 10 mBq/m3, and a 226Ra concentration better than 1 mBq/m3. For the filling water and the water extraction system, the required radiopurity must be 1–2 orders of magnitude better than that of the WCD water. Specifically, for the filling water, which contacts only the surface of the LS, the radiopurity is required to be one order of magnitude better than that of the WCD water. In contrast, for the water extraction system used to purify the LS, the water is fully mixed with the LS; therefore, its radiopurity must be two orders of magnitude better than that of the WCD water.
Material Mass
[t]Target impurity concentration Singles 238U
[10−9 g/g]232Th
[10−9 g/g]40K
[10−9 g/g]210Pb
[10−9 g/g]60Co
[mBq/kg]DV
[Hz]FV
[Hz]LS-reactor 20000 10−6 10−6 10−7 10−13 2.5 2.2 Acrylic 610 10−3 10−3 10−3 8.4 0.4 SS structure 1000 1 3 0.2 20 15.9 1.1 65 0.2 0.6 0.02 1.5 PMT glass 33.5 400 400 40 26.2 2.8 100.5 200 120 4 2.6 400 400 200 PMT readout 125 68 194 5 16 3.4 0.4 16.3 93 243 12 14 Other 2.5 0.3 Sum 59 7.2 Table 1. The final background budget for the main materials used in the JUNO detector, for events with reconstructed energies greater than 0.7 MeV, is taken from Ref. [9]. The two rows for the SS structure correspond, respectively, to the SS shell positioned farther from the LS and to the SS joints and supporting bars located closer to the LS. The three rows labeled PMT glass correspond, in order, to 20-inch dynode-PMTs, 20-inch MCP-PMTs, and 3-inch PMTs. The two rows under PMT readout correspond to the readout electronics for the 20-inch and 3-inch PMTs, respectively. The expected count rates are reported for both the full detector volume (R = 17.7 m) and the default fiducial volume (R = 17.2 m).
To achieve the objectives outlined in Table 1, we meticulously screened thousands of samples during the selection and production of detector raw materials. Finally, those with the lowest levels of natural radioactivity were selected for the construction of JUNO.
The paper is organized as follows. Section 2 provides a brief overview of the screening facilities and instrumentation within the collaboration used to quantify the radiopurity of detector components. Section 3 summarizes the measurement results for all raw materials used in the JUNO detector. Section 4 presents results from initial detector data and compares them with the design expectations. Finally, Section 5 summarizes this research.
-
The methods commonly used to measure natural radioactivity (U, Th, K) in materials primarily include three techniques: high-purity germanium (HPGe) gamma spectrometry, neutron activation analysis (NAA), and inductively coupled plasma mass spectrometry (ICP-MS). Each detection method has its own advantages and limitations, and their main performance characteristics are compared in Table 2. The sensitivity is expressed in Bq/kg or in mass concentration units
1 (g/g, i.e., grams of contaminant per gram of material). For a few acrylic samples, U/Th surface contamination was also measured by laser ablation ICP-MS (LA-ICP-MS). To ensure that the radon level in the water is as low as possible, several facilities for radon emanation and radon permeability measurements were used. A detailed description of the screening facilities used for JUNO samples is provided in Ref. [9], to which we refer for further details. In practical measurements, the appropriate analytical method is selected based on a comprehensive consideration of the design specifications and the strengths and limitations of the available techniques. For particularly critical components, multiple methods may be applied.HPGe NAA ICP-MS Nuclei 238U, 226Ra, 228Ra,228Th, 40K, 60Co 238U, 232Th, 40K, 85Kr 238U, 232Th Destructive testing No Yes/No Yes Decay chain equilibrium check Yes No No Treatment No Simple Complex Sample mass [kg] 0.1-20 0.001-0.05 0.001-0.01 Sample mass with enrichment [kg] - 0.05-2 0.1-10 Sensitivity (0.1-100) mBq/kg (10−12-10−16) g/g (10−12-10−17) g/g Time [day] 1-30 10-30 2-5 Table 2. The table compares the advantages and disadvantages of the three detection methods. The sensitivity range and testing time depend on the sample type.
Compared with the instrumentation and sensitivity reported in Ref. [9], our quality inspection capabilities have been further enhanced. For LS screening, novel methods have been developed for both ICP-MS and NAA. These methods extract U/Th from the LS using nitric acid and subsequently concentrate the acid solution. For ICP-MS, after 3–5 days of experimental processing, the measurement sensitivity for U/Th can reach 10−16–10−17 g/g [10]. This technique has been extensively applied in the quality assurance/quality control (QA/QC) processes during LS production and filling for JUNO. For NAA, after the pre-concentration step and neutron irradiation, radiochemical separation combined with
$ \beta-\gamma $ coincidence spectroscopy was implemented, allowing sensitivities for U/Th in the range of 10−15–10−16 g/g [11]. For K, no pre-concentration step is required; only radiochemical separation is performed after neutron irradiation of the LS, followed by gamma spectroscopy. This method achieves sensitivities at the level of 10−16 g/g [12].For radiopurity measurements of acrylic samples, we have developed a rapid and sensitive method to quantify 238U and 232Th below 10−12 g/g within 2–3 days, based on microwave ashing coupled with ICP-MS analysis [13]. Compared with the previous approach [14], this method is significantly simpler, safer, and more efficient. It has been extensively implemented in the QA/QC procedures (described in Section 3.1) during the production and surface treatment of acrylic components for the JUNO experiment. Cross-check measurements using NAA and the method described in [15] have been performed periodically.
We have significantly improved the sensitivity of our instrumentation for measuring radon levels in both gas and water. The achieved sensitivities reach 0.26 µBq/m3 for radon measurements in nitrogen [16] and 0.6 mBq/m3 for radon measurements in water [17]. In addition, by using manganese wire to concentrate radium in water and coupling it with radon detection devices, we have developed a method capable of measuring radium concentrations in water down to 6 µBq/m3 [18]. This method has been used for quality control of ultrapure water in JUNO.
-
In this section, the quality inspection results for all detector materials that meet the JUNO requirements are systematically summarized by detector subsystem, following the categories listed in Table 1. These results were obtained from several years of screening activities, during which only materials with sufficiently low contaminant concentrations were retained. Because different analytical techniques probe different radionuclides in the natural 238U and 232Th decay chains, the quality control results are organized accordingly. Measurements of the parent radionuclides obtained using ICP-MS and NAA are presented separately from results based on the assumption of decay-chain equilibrium, which are derived from HPGe spectrometry. When a sample is annotated with “(XX batches)”, the reported result corresponds to the average of multiple production batches. Results without this notation are based on a single measurement. For critical materials, multiple batches were screened to ensure consistency.
-
These two techniques were used for materials whose radiopurity is critically important, requiring screening of 238U and 232Th concentrations well below 10−12 g/g. This requirement applies to all materials very close to or in direct contact with the LS, including the LS itself, as listed in Table 3. For ICP-MS screening of water and LS, sample enrichment is required, and the processed sample mass typically ranges from 0.1 to 10 kg, depending on the target sensitivity. In contrast, other material samples analyzed by ICP-MS generally require only a few grams and do not undergo an enrichment step. For NAA, sample masses on the order of 10–50 g were irradiated directly for organic matrices, whereas LS samples required pre-concentration, with processed masses up to 2 kg.
Type Material Producer Mass for JUNO Technique 238U [10−12 g/g] 232Th [10−12 g/g] 40K [10−12 g/g] LS LAB (37 batches) SINOPEC, Nanjing, China 20,000 t ICP-MS (0.6±0.1)×10−3 (1.0±0.1)×10−3 - PPO (19 batches) HAISO, Wuhan, China 60 t ICP-MS 0.09±0.02 0.07±0.02 - PPO (2 batches) 60 t NAA <0.3 <0.5 1.24±0.03 BHT (2 batches) 1 t ICP-MS 0.14±0.03 0.07±0.04 - BHT 1 t NAA <3.0 <3.0 3.8±0.2 bis-MSB (3 batches) 72 kg ICP-MS 2.9±0.1 2.0±0.1 - Final LS JUNO 20,000 t ICP-MS <3.4×10−5 <3.3×10−5 - Final LS 20,000 t NAA <6.5×10−4 <1.8×10−3 <2×10−4 Water For water-extraction JUNO 6,700 t ICP-MS <2.6×10−4 <1.0×10−5 For detector filling 23,200 t ICP-MS (4±1)×10−4 <4×10−4 For water Cherenkov detector 40,000 t ICP-MS (5±1)×10−4 <4×10−4 Filled CD water surface - ICP-MS (1.05±0.06)×10−3 (3.7±0.7)×10−4 Organic materials Acrylic panels (44 batches) Donchamp, Taixing, China 600 t ICP-MS 0.62±0.05 0.72±0.05 - Acrylic panels (13 batches) Donchamp, Taixing, China 600 t NAA <0.2 <0.1 0.1-0.4 Acrylic surface ( $ \sim $ 10 µm)- - ICP-MS 15.2±0.7 24.3±0.7 - Acrylic subsurface ( $ \sim $ 65-75 µm)- - LA-ICP-MS 3.9±0.6 6.8±0.8 - PMT acrylic cover Huashuaite, Jiaxing, China 110 t ICP-MS 3.1±0.3 10±1 - Teflon in acrylic node BMC, Kunshan, China 300 kg NAA 16±2 82±5 283±11 Epoxy (type 8010) for
acrylic bonding lineDODI, Shanghai, China 3 kg ICP-MS <5 <7 - Water-soluble glue on film Elleair, Japan - ICP-MS 450±20 115±6 - Calibration CLS anchors, PTFE Sanxin Inc., China 6.3 kg NAA <1.2 10±2 1.50±0.05 Calibration wear-resisting
blocks, PTFESanxin Inc., China 6.9 kg NAA <1.2 10±2 1.50±0.05 Calibration GTCS Tube, PTFE Jianwei, China 20 kg NAA <1.65 <3 470±10 Table 3. This table lists the JUNO samples analyzed using the destructive analytical methods ICP-MS and NAA. The upper limits for most materials listed in the table are reported at 95% C.L., whereas those for calibration components are reported at 90% C.L.
The final JUNO LS mixture consists of four components at different concentrations. The base solvent is linear alkylbenzene (LAB), doped with 2.5 g/L of 2,5-diphenyloxazole (PPO) as the primary fluor, 3 mg/L of 1,4-bis(2-methylstyryl)benzene (bis-MSB) as the wavelength shifter, and 42.7 mg/L of butylated hydroxytoluene (BHT) as the antioxidant. Table 3 reports the radiopurity screening results for the individual components. The LS mixture was prepared and purified directly at the JUNO site [2]. The raw LAB produced by SINOPEC first undergoes alumina (Al2O3) filtration to reduce optical impurities and is subsequently processed in a distillation plant [19] to remove heavy contaminants. The mixing system then produces the LS cocktail, which is further purified underground by water extraction to remove heavy metals and by gas stripping [19] to eliminate volatile impurities. The purified LS is finally stored in the Filling and Overflow Control (FOC) system before being transferred into the acrylic vessel. During LS production for JUNO, samples were taken regularly after each purification step to monitor and validate the radiopurity. The results obtained by ICP-MS [10] are summarized in Figure 2. The screening results from the distillation system during commissioning were consistently below the ICP-MS detection limit. Therefore, samples from stages up to and including distillation were analyzed only at the beginning of production, whereas subsequent samples were taken from later stages (mixing, water extraction, gas stripping, and FOC systems) to optimize the use of measurement resources. For the water extraction system, an initial cleanliness issue was identified at the start of production. Consequently, this system was used only after its cleanliness had been confirmed by ICP-MS, and it became operational on March 25, 2025. Most of the screening results shown in the figure were below the ICP-MS detection limit. In June and July 2025, some FOC system screening points yielded measured contaminant concentrations rather than upper limits, whereas the gas stripping samples provided only upper limits. This discrepancy is tentatively attributed to possible sampling contamination, although it has not been conclusively verified. Table 3 summarizes the average LS screening results from the FOC system, obtained after all purification steps defined by the JUNO protocol [2] and before detector filling.
Figure 2. Time evolution of the ICP-MS screening results for U/Th concentrations in LS during the filling of the JUNO detector in the first half of 2025. Top left: "MIX" denotes the mixing system. Top right: "WE" denotes the water extraction system. Bottom left: "GS" denotes the gas stripping system. Bottom right: "FOC" denotes the filling and overflow control system.
Water is another crucial material for the JUNO detector. In addition to being the main component of the water Cherenkov detector, it was used in the water-extraction purification step [19] for the LS and in the water-exchange filling procedure [7] adopted to fill the JUNO detector. After filling the acrylic sphere with ultrapure water (UPW), we collected surface water samples from the top chimney. Extensive measures were implemented to ensure detector cleanliness [20], and this measurement serves as an indicator of both the internal environment and the cleanliness of the acrylic surface. The results for the different samples are reported in Table 3, and all samples meet the filling water requirement of U/Th<10−15 g/g. This indicates that both the internal environment of the acrylic vessel and its surface remained very clean after installation. The 222Rn and 226Ra activities in water were measured using the methods described in Refs. [17, 18]. For the water extraction system, the measured 222Rn activity in UPW was below 1 mBq/m3, while for the water Cherenkov detector it was below 10 mBq/m3. The 226Ra activity in UPW was below 10 µBq/m3 for both the water Cherenkov detector and the water extraction system.
The acrylic vessel, as anticipated in Section 1, was constructed on site by bonding 263 acrylic panels layer by layer. All batches of acrylic panels were screened by ICP-MS to verify their radiopurity; the results are shown in Figure 3, and the average values are summarized in Table 3. After production, the panels were stored temporarily at the manufacturer’s facility, with their surfaces protected by a polyethylene (PE) film. LA-ICP-MS measurements revealed that the radioactive contamination in the top 50 µm of the surface could be 2–3 orders of magnitude higher than that in the bulk material. Therefore, it was decided to remove at least 100 µm from the surface before shipment to the JUNO site.
Figure 3. Evolution of ICP-MS screening results for U/Th concentrations in acrylic during the production of panels for the acrylic vessel.
Following a detailed study of potential background contamination during the surface-treatment process, the final procedure was implemented for the JUNO acrylic-panel production [13]. In Table 3, acrylic surface refers to surface scrapings from a specified thickness of the acrylic panels, measured to assess the residual radioactive contamination after surface polishing. After careful surface treatment, each panel was covered with a water-soluble paper film to protect it from dust and the implantation of radon daughters until detector filling. Moreover, each bond line was sealed with a special epoxy to prevent chemical reactions with the LS during long-term operation. Acrylic covers were also manufactured to protect the glass of the 20-inch PMTs from chain explosions—a phenomenon in which the explosion of one PMT generates a shock wave in water that triggers the explosion of adjacent PMTs, resulting in a chain reaction.
-
For HPGe detectors, only gamma-ray lines from the decay daughters of the 238U and 232Th chains—starting from 226Ra and 228Ra onward—can be measured. At sufficiently high concentrations of 238U, γ-ray lines from 234Th and 234mPa may also be observed. However, in our background simulations, we assume secular equilibrium throughout the entire decay chains. The gamma spectrometers used for material screening in JUNO are HPGe detectors protected by passive and/or active shielding and located in several underground laboratories worldwide (China Jinping Underground Laboratory (CJPL) in China, Laboratoire Souterrain de Modane (LSM) in France, and Laboratori Nazionali del Gran Sasso (LNGS) in Italy) or in sea-level laboratories (IHEP in China, LP2i Bordeaux in France, and UNIMIB in Italy). The sample mass ranges from 0.1 to 15 kg, depending on the geometry and density of the material.
A system-by-system overview of the HPGe quality screening for JUNO materials is presented in Tables 4–8. Owing to the limited sensitivity to 60Co at the level of 10 mBq/kg, screening results for this isotope obtained at IHEP are not included.
CD and LS Material Producer Mass for
JUNOScreening 226Ra
[Bq/kg]228Ra
[Bq/kg]40K
[Bq/kg]60Co
[mBq/kg]LS PPO HAISO, Wuhan, China 60 t UNIMIB <0.2 <0.03 <0.3 <0.01 Al2O3 SHAN LV YI FENG,
Zibo, China300 t IHEP 0.26±0.03 <0.22 <0.70 - Acrylic node Bulk, SS304 (2 batches) TISCO, Taiyuan, China 24 t CJPL <4×10−3 (2.8±0.7)×10−3 <0.05 0.7±0.3 Bolt, SS304 CJPL (7±5)×10−3 (8±2)×10−3 0.05±0.04 2±1 Solder Φ1.2, SS308 Golden Bridge, Tianjin, China 4.5 t IHEP 0.39±0.08 0.15±0.10 2.4±0.5 - Support rod Bulk, SS304 (8 batches) TISCO, Taiyuan, China 67 t CJPL <4×10−3 (2±1)×10−3 0.05±0.03 2.0±0.7 Bulk, SS304 67 t LNGS (0.3±0.1)×10−3 (0.8±0.3)×10−3 <2.8×10−3 (0.4±0.1)×10−3 SS truss Bulk, SS304 (17 batches) TISCO, Taiyuan, China 608 t CJPL (6±2)×10−3 (3±1)×10−3 (4±2)×10−3 1.4±0.5 Bulk, SS304 608 t LP2IB <1.1×10−3 (4.7±0.7)×10−3 <9×10−3 0.50±0.15 Bolt, SS630, SS 65 t CJPL <4×10−3 (6±3)×10−3 0.17±0.07 10±3 Ring gasket, SS CJPL <4×10−3 (1.5±0.7)×10−2 0.3±0.1 11±2 Spring, SS 10 t IHEP <0.11 <0.06 <0.35 - Paint, SS NIMTE, Ningbo, China CJPL (2.4±0.7)×10−2 (1.9±0.3)×10−2 0.43±0.05 3±2 Solder Φ3.2, SS308 Golden Bridge, Tianjin, China 8.9 t IHEP 0.17±0.07 0.21±0.06 <1.3 - Chimney Bulk, SS304 TISCO, Taiyuan, China IHEP <0.12 <0.15 <0.6 - Bellow, SS304 CJPL (8±5)×10−3 <5×10−3 0.04±0.03 12±2 Bolt, SS304 48 kg CJPL (1.3±0.7)×10−2 (4±2)×10−3 0.09±0.05 11±2 LS and FOC Tank and pipes,
SS316 (2 batches)TISCO, Taiyuan, China 50 t CJPL <4×10−3 (6±2)×10−3 0.09±0.05 3±2 Acrylic Vessel Acrylic sample Donchamp, Taixing, China 600 t LNGS <45×10−6 <62×10−6 <0.3×10−3 - Acrylic surface
treatmentSanding paper Anda, Taixing, China 106 pieces IHEP <0.5 <0.4 <1.9 - PE film Baojiali, Nantong, China 105 m2 IHEP <0.23 <0.15 <0.9 - Protection paper film Daio Paper Corporation, Japan 104 m2 IHEP <0.5 0.6±0.2 <1.6 - Table 4. This table lists the CD- and LS–related samples analyzed using non-destructive HPGe assay methods. The upper limits reported in this table are given at 95% C.L., except for the LNGS measurements, which are quoted at 68% C.L.
Calibration Material Producer Mass for
JUNOScreening 226Ra [Bq/kg] 228Ra [Bq/kg] 40K [Bq/kg] 60Co [mBq/kg] USS Cables
(PTFE, copper)Pasterneck, USA 1.45 kg CJPL (3.4±0.5)×10−3 (1.9±0.5)×10−3 (1.7±0.4)×10−2 <0.4 Receiver
(Ni, epoxy, PCB)Customized, China 10 pieces CJPL <3.3 mBq/piece <2.8 mBq/piece <19 mBq/piece <0.86 mBq/piece CLS Cables (PTFE, SS) Fengshuo, China 0.27 kg CJPL <0.06 <0.08 <0.5 <38 GTCS Cable (PTFE, SS) Fengshuo, China 0.33 kg CJPL <0.04 <0.04 <0.14 (2.9±0.1)×102 Sensor
(SS, PVC, PBT)Omron, Japan 10 pieces CJPL (111±3) mBq/piece (184±5) mBq/piece (383±21) mBq/piece <2.9 mBq/piece CCD Camera OPT, Dongguan, China 4.4 kg IHEP 0.7±0.3 3.3±0.4 12±2 - Cable Fanya, Zhongshan, China 0.01 t IHEP <0.36 <0.27 <1.4 - Fibre-optical HongXin, Dongguan,
China0.4 t IHEP <0.3 <0.17 <1.0 - Table 5. This table lists the JUNO calibration-related samples analyzed using the non-destructive HPGe testing method. The upper limits reported in this table are given at 90% C.L.
PMT Material Producer Mass for
JUNOScreening 226Ra
[Bq/kg]228Ra
[Bq/kg]40K
[Bq/kg]60Co
[mBq/kg]Bulb Module, SS304 (3 batches) JISCO, Gansu, China 300 t CJPL <0.01 <2×10−3 <0.03 <1.5 20-inch PMT cover,
SS304 (3 batches)150 t CJPL <0.01 <5×10−3 <0.03 <3 20-inch MCP-PMT (10 batches) Huida, Yancheng, China 90 t IHEP 1.9±0.2 0.6±0.2 <1.4 - 20-inch dynode-PMT (6 batches) Hamamatsu, Japan 30 t IHEP 5.3±0.2 1.4±0.3 1.7±0.2 - 20-inch dynode-PMT 30 t LP2IB 6.5±0.2 2.3±0.1 1.9±0.3 - 20-inch dynode-PMT 30 t UNIMIB 5.4±0.2 1.9±0.1 1.7±0.3 - 3-inch PMT (8 batches) Zhanchuang, Hainan, China 2.6 t IHEP 2.2±0.2 1.7±0.2 29±2 - 3-inch PMT 2.6 t LP2IB 2.7±0.2 2.8±0.2 32±2 - Potting 20-inch PMT shell,
SS304 (2 batches)JISCO, Gansu, China 10 t CJPL <6×10−3 (5±3)×10−3 0.06±0.02 0.9±0.5 3-inch PMT shell, ABS Kemei, Ningbo, China 6.4 t IHEP <0.32 <0.22 8.2±0.9 - Putyl tape (type HM36) AECC BIAM, Beijing, China 5.7+2.5 t IHEP 2.2±0.2 0.4±0.1 <1.5 - 20-inch PMT Epoxy (type 8101R) DODI, Shanghai, China 2.8 t IHEP 0.30±0.04 0.08±0.03 <1 - 3-inch PMT Epoxy (type 4412) Buffle, Beijing, China 0.5 t IHEP <0.2 0.39±0.06 <0.6 - Polyurethane (type 6127) Buffle, Beijing, China 15+2 t IHEP <0.29 <0.21 <1.2 - Shrinkable tube WOER, Shenzhen, China 2.5+0.5 t IHEP <0.27 <0.18 <0.9 - Divider 20-inch PMT PCB - - IHEP 15±1 19±2 17±5 - 20-inch PMT capacitors Vishay, USA - IHEP 131±5 18.8±0.9 3±1 - 20-inch PMT resistors Vishay, USA - IHEP 2.0±0.2 2.1±0.2 10±1 - Divider for MCP-PMT TJcentre, Tianjin, China 0.44 t IHEP 34±3 15±3 <22 - Divider for dynode-PMT TJcentre, Tianjin, China 0.16 t IHEP 36±4 19±3 21±11 - 3-inch PMT PCB - 0.11 t IHEP 35±2 38±2 52±3 - 3-inch PMT chip resistors Viking, Taiwan, China - IHEP 1.4±0.2 2.3±0.2 2.0±0.8 - 3-inch PMT PCB+resistors - 0.11 t LP2IB 31±3 31±2 29±4 - 3-inch PMT capacitors Murata, Japan 0.04 t IHEP 13.6±0.6 5.6±0.5 4±1 - 3-inch PMT capacitors Murata, Japan 0.04 t LP2IB 12.2±2.2 5.8±1.3 <5.5 - Divider for 3-inch PMT Juyingdianlu, Shenzhen, China 0.25 t IHEP 29±1 34±2 42±3 - Table 6. This table lists the JUNO PMT-related samples analyzed using the nondestructive HPGe testing method. The reported upper limits are given at the 95% C.L.
Electronics Material Producer Mass for
JUNOScreening 226Ra
[Bq/kg]228Ra
[Bq/kg]40K
[Bq/kg]60Co
[mBq/kg]Common materials
for all PMTsSS shell GL, Kunshan, China 78+6.2 t IHEP <0.11 <0.07 0.3±0.2 - Shrinkable tube WOER, Shenzhen, China 0.6 t IHEP <0.17 <0.14 <0.5 - Thermal gel GLPOLY, Shenzhen, China 3.5+0.06 t IHEP 0.83±0.08 0.27±0.06 <0.7 - Thermal copper Futelang, Suzhou, China 15 t IHEP <0.05 <0.03 <0.2 - Back-end cable Fanya, Zhongshan, China 68 t IHEP <0.18 <0.12 <0.6 - Back-end below Taihe, Wuhu, China 72 t IHEP <0.21 <0.13 <0.8 - 20-inch PMTs HVB PCB GDM, Shanghai, China 0.20 t IHEP 10±1 18±2 17±6 - HVB metal box (Al) Juchuangli, Shenzhen, China 0.22 t IHEP <0.17 <0.10 <0.49 - Entire HVB SCC, Shenzhen, China 0.9 t IHEP 3±1 5±1 <18 - GCU board SCC, Shenzhen, China 1.9 t IHEP 8.8±0.5 12.0±0.7 13±1 - Cooling appendix (copper) Futelang, Suzhou, China 0.6 t IHEP <0.1 <0.07 <0.3 - Front-end cable Fanya, Zhongshan, China 1.7 t IHEP 0.9±0.4 0.5±0.3 <8 - Front-end below (SS) Taihe, Wuhu, China 4.4 t IHEP 0.11±0.05 <0.10 0.4±0.3 - 3-inch PMTs HV splitter board SCC, Shenzhen, China 0.4 t LP2IB 13.8±1.1 17.1±1.2 16.9±3.0 - GCU board 0.07 t LP2IB 6.0±0.3 7.1±0.4 46.4±6.1 - ABC front-end board FEDD, Agôn Electronics,
France0.07 t LP2IB 6.7±0.5 9.3±0.5 5.3±1.1 Front-end cable Axon, Foshan, China 1.4 t LP2IB (5.6±1.7)×10−3 <4.2×10−3 <25×10−3 <1 Connector+Front-end cable Axon, Foshan, China 2.8 t IHEP 0.8±0.3 1.0±0.3 <1.8 Table 7. This table lists the JUNO electronics-related samples analyzed using the non-destructive HPGe testing method. The upper limits reported in this table are given at 95% C.L.
Veto Material Producer Mass for JUNO Screening 226Ra [Bq/kg] 228Ra [Bq/kg] 40K [Bq/kg] 60Co [mBq/kg] Earth magnetic field coils Zhenshi, Jiaxing, China 168 t IHEP <0.16 <0.09 <0.4 - HDPE GSE, Thailand 7500 m2 IHEP <0.19 0.17±0.05 0.8±0.5 - Truss column base, SS TISCO, Taiyuan, China 2 t IHEP <0.16 <0.10 <0.46 - Solder Golden Bridge, Tianjin, China - IHEP <0.14 <0.09 <0.4 - Table 8. This table lists the JUNO veto-related samples analyzed using non-destructive HPGe testing methods. The upper limits reported in this table are at the 95% C.L.
Table 4 reports the HPGe screening results for most of the materials used to build the central detector (CD) and the LS purification system, namely the LS, the acrylic vessel, the SS truss, and the supporting rods. The LS and FOC measurements refer to the stainless steel used for the LS purification system and the FOC system [2], i.e. all pipes and tanks employed for LS filling and level control in the detector.
Table 5 reports the HPGe screening results for most of the materials used in the calibration system, namely the USS, CLS, GTCS, and CCD.
Table 6 reports the HPGe screening results for the main materials used in the PMT system, namely the glass bulb, the potting materials, and the voltage divider components. Of the nearly 20,000 20-inch PMTs deployed in the JUNO detector, approximately 5,000 were dynode-PMTs procured from Hamamatsu, while the remaining 15,000 were MCP-PMTs supplied by NNVT. The glass envelopes for the MCP-PMTs were manufactured in China, providing an opportunity for close collaboration with the supplier to optimize the production line. The production of the PMT bulbs required extensive screening of low-background raw materials and careful control of potential secondary contamination introduced during manufacturing from the environment, tools, or contact materials. To mitigate these effects, a dedicated background control program was implemented at the manufacturer's site, including on-site supervision by members of the collaboration and the optimization of cleanliness procedures throughout the production chain [21]. These measures significantly reduced the U, Th, and K contents of the MCP-PMT glass, reaching levels comparable to the best values reported for large photomultiplier tubes. During mass production, representative batches of bulbs were periodically screened by HPGe to verify their radiopurity, and the average results are summarized in the table. Since all PMTs and their associated electronics are operated underwater, the waterproof encapsulation at the PMT rear end must meet extremely high standards. The measurement data for these potting materials are compiled in the "Potting" section.
Table 7 reports the HPGe screening results for most of the materials used in the electronics system, including the housing, heat dissipation structure, high-voltage module, Global Control Unit (GCU) board, front-end board for 3-inch PMTs, as well as the cables and waterproof flexible conduits that run from the PMT back-end to the dry electronics racks in the experimental hall.
Table 8 reports the HPGe screening results for most of the materials used in the veto system, including the geomagnetic-field compensation coils, the high-density polyethylene (HDPE) used to prevent the diffusion of radon from rock strata and groundwater, and the truss column base structure fixed at the bottom of the pool.
-
Radon in the 238U chain is a radioactive noble gas that can diffuse through barriers or emanate from JUNO materials immersed in the water pool. The JUNO requirement for the radon activity concentration in the water pool is 10 mBq/m3. To prevent radon from rock and groundwater from diffusing into the ultrapure water, a 5-mm-thick HDPE layer was installed against the rock surface. The shielding effectiveness can be evaluated based on the permeability of radon through HDPE (so-called transparency). This transparency is determined by placing a radon source on one side of the HDPE and measuring the radon concentration on the opposite side to calculate the radon penetration ratio. The transparency of a 5-mm-thick HDPE liner has been measured with a dedicated apparatus in two configurations: one with air on both sides of the HDPE liner and one with water on one side and air on the other, which is more representative of JUNO. The results are given in Table 9. The presence of water is observed to increase the radon transparency by a factor of 5–6. Nevertheless, the 5-mm-thick HDPE layer remains effective at blocking radon from the rock side under water-filled conditions.
Material Producer Configuration Screening Transparency 5 mm HDPE liner GSE, Thailand air / air (3 samples) CPPM (2.6±0.4)×10−5 air / water (2 samples) (14.2±0.9)×10−5 Table 9. This table presents the radon transparency measurements for the HDPE liner.
Table 10 lists the JUNO samples screened by radon emanation measurements in nitrogen, including the bare 20-inch and 3-inch PMTs and the HDPE liner. Further details of the setup are provided in [22].
Material Producer Quantity measured / Total Screening Radon emanation 5 mm HDPE liner GSE, Thailand 2 m2 / $ \sim $ 6500 m2LP2IB <1.8 mBq/m2 20-inch bare PMTs Huida, Yancheng, China 2 / 15056 LP2IB <1.9 mBq/PMT 20-inch bare PMT Hamamatsu, Japan 1 / 4939 LP2IB <3.4 mBq/PMT 3-inch bare PMTs Zhanchuang, Hainan, China 29 / 25587 LP2IB <0.13 mBq/PMT Table 10. This table presents the radon emanation measurements. The upper limits are reported at the 90% C.L.
-
The radionuclide 14C is an important background source in the low-energy region relevant to solar neutrino analyses. In addition, its high decay rate can cause pile-up with other physics events within a single readout window, degrading the energy resolution and thereby substantially affecting reactor antineutrino measurements. For these reasons, the 14C concentration was measured in several LAB samples, including those produced for the JUNO experiment. The detector used for this purpose is located in the JUNO underground laboratory (650 m.w.e.) and is surrounded by a multilayer passive shield consisting of acid-cleaned oxygen-free high-conductivity (OFHC) copper, lead, 1 cm of HDPE, and 60 cm of borated polyethylene for neutron attenuation. The entire setup is enclosed in a light-tight, radon-suppressed environment maintained by a continuous purge of high-purity nitrogen (>100 L/h). The system employs 0.86 kg of LS contained in a 1-L transparent acrylic vessel (76 mm inner diameter, 2 mm wall thickness), viewed by two low-radioactivity Hamamatsu R1140-20 PMTs. These PMTs have a quantum efficiency of 35% at 420 nm and a U/Th radiopurity of approximately 1 mBq per PMT. A coincidence trigger–set at a threshold of approximately 1 photoelectron (p.e.) with a 44 ns time window–is used to suppress dark noise and accidental background events. The key results obtained with this setup are summarized in Table 11. The systematic uncertainty of 20% is dominated by the detector configuration and light yield.
Sample Identifier 14C Concentration [10−17 g/g] Average of 8 times sampling in 2023 2.8 ± 0.2 (stat.) ± 0.6 (sys.) OSIRIS storage tank (2023.11) 3.4 ± 0.2 (stat.) ± 0.7 (sys.) JUNO LAB tank (2024.11.20) 3.3 ± 0.4 (stat.) ± 0.7(sys.) Table 11. Summary of 14C concentration measurements for various LAB samples.
-
JUNO completed detector construction and LS filling on August 26, 2025, and officially began data collection [7]. In this study, we analyzed the event distribution in the LS using data collected from October 1, 2025, to March 18, 2026, beginning approximately one month after filling was completed. The total live time of the dataset is 140 days. By this stage, radon introduced during the filling operations had decayed to a nearly constant background level. Vertex and energy reconstruction for all events follows the procedure detailed in Ref. [7], with several post-publication refinements incorporated. The resulting position reconstruction bias is constrained to within 10 cm, and the measured energy resolution is 3.4% at 1 MeV using the 68Ge calibration source.
Our objective is to extract the event rate originating from natural radioactivity using experimental data, which requires excluding contributions from non-radioactive events as thoroughly as possible. Simulations indicate that radioactive events typically have energies below approximately 5 MeV. In contrast, cosmic muons have much higher energies. As they traverse the detector, they produce large numbers of secondary particles, some of which may deposit energy in the same low-energy range and thus contaminate the radioactive event sample. Therefore, in this analysis, a single event is defined as an event recorded in the CD after the muon veto has been applied.
The muon definition and muon-veto strategy are the same as those in Ref. [3]. Muon candidates were identified as CD triggers with charge Q>3×104 p.e. or water pool (WP) triggers with Q>700 p.e. We vetoed the full CD for 5 ms following each muon event. This results in a live time efficiency of 95%, which is included in the results presented below.
Apart from potential reconstruction bias, the top and bottom of the JUNO CD are each equipped with an approximately 1-meter-long acrylic chimney section filled with LS. Owing to the thinner water shielding in these regions and the distinctive optical paths of such events, some events originating in the chimneys are reconstructed inside the detector volume (R<17.7 m). To address this issue, dedicated variables for identifying chimney events have been developed in the reconstruction algorithm and can efficiently reject misreconstructed chimney events. A rejection efficiency of 99% is achieved for the region R<17.2 m, while the impact on standard physics events is kept below 1%. A detailed study of chimney event tagging will be presented in the subsequent reconstruction paper. Therefore, the chimney event selection criterion is adopted in the event selection of this study to effectively suppress interference from chimney events.
The event rate distributions in the outer region of the detector for 17.2 m<R<17.5 m and 17.5 m<R<17.7 m are shown in the left and right panels of Figure 4, respectively. The bright spots in the left panel primarily originate from background contributions from acrylic nodes and SS support rods on the outer surface of the acrylic vessel. These components are located closer to the detector, and the gamma rays produced by natural radioactive decay can penetrate deeper. In contrast, the events in the right panel are located closer to the edge and mainly originate from the PMT contribution. Because the PMTs are farther from the LS, with nearly two meters of water shielding, their contribution becomes less significant than that of the acrylic nodes on the outer surface of the acrylic vessel for R<17.5 m.
Figure 4. The x–z distributions of the event rate in the LS over the energy range 0.7–6 MeV are shown for two radial cuts: 17.2 m<R<17.5 m (left) and 17.5 m<R<17.7 m (right).
Figure 5 shows the time evolution of the event rate in the LS for the baseline FV (with R<17.2 m). A gradual decreasing trend is observed, potentially attributable to the combined effects of residual radon decay and purification of the circulating veto water. A small increase in the event rate was observed in early December and late January. The cause remains unknown; possible explanations include water-temperature-induced shifts in the liquid scintillator temperature and the ensuing convection.
Figure 5. Time evolution since October 2025 of the rate of events with energies greater than 0.7 MeV in the LS FV within R<17.2 m.
A comparison of the event rate in the LS as a function of position between data (from February 5 to March 18, 2026) and the MC simulation [9] is shown in Figure 6. The figure presents the event rate (for events with E>0.7 MeV) for different FV cuts. Each data point represents the total event rate within the volume defined by R<FV, with the dashed line indicating the baseline selection of R<17.2 m. The dominant uncertainty arises from position reconstruction. The uncertainties of the data points are estimated from the variations in event rates caused by position-reconstruction bias, which is derived from the 68Ge calibration source at different z positions. For each data point, we shift its position to the left and right by the corresponding reconstruction bias, compute the event-rate difference between these shifted positions and the original position, and assign this difference as the uncertainty shown in the plot. A detailed numerical comparison between data and simulation is provided in Table 12. The leading systematic uncertainty originates from event reconstruction, whose performance will be further improved in future iterations. The JUNO Collaboration has developed multiple event reconstruction algorithms. Relative to alternative reconstruction implementations, discrepancies in the FV singles rates currently amount to approximately 20–30%. This is mainly due to systematic differences in the reconstructed positions of events occurring near the acrylic vessel. Elsewhere, all algorithms agree closely with one another. The results show that the measured radioactive background from the LS and detector materials within the baseline FV is lower than the design value used in the MC simulations. This improvement is consistent with the measured internal radiopurity of the LS, which is approximately one order of magnitude below the design baseline requirement of 10−15 g/g for U/Th. As indicated in Table 1, this difference would contribute
$ \sim $ 2 Hz to the LS event rate.
Figure 6. The figure compares the event rate as a function of the fiducial-volume cut for data collected from February 5 to March 18, 2026 (orange), with the MC simulation from Ref. [9] (blue). The uncertainties on the data points are calculated from the event-rate variations induced by position-reconstruction bias. The dashed line indicates the baseline selection, R<17.2 m.
Rate [Hz] Fiducial volume Design LS (10−15 g/g U/Th) 2.2 Other detector material 5 Data LS + Other detector material 4.7 Table 12. The table compares the event rates above 0.7 MeV within the fiducial volume (R<17.2 m), as obtained from design simulations and experimental data collected from February 5 to March 18, 2026.
-
To ensure that the detector achieved sufficiently low background levels, JUNO implemented a rigorous screening campaign to characterize the natural radioactivity of materials during both the R&D and construction phases, involving assays of several thousand samples. This paper presents the quality control results for all materials ultimately deployed in the detector. Using data collected after the completion of LS filling for the JUNO detector, we performed a detailed analysis of the event rate and compared the results with the original MC simulations. The radial distribution of the event rate agrees well with the simulations. The event rate inside the FV meets the design specifications and satisfies the requirements for reactor neutrino oscillation studies.
Final assessment of radioactive impurities in the JUNO detector
- Received Date: 2026-07-21
- Available Online: 2026-10-01
Abstract: The Jiangmen Underground Neutrino Observatory (JUNO) collaboration has completed construction of the 20,000-ton liquid scintillator detector and the associated muon veto detector system. To achieve its physics objectives, the materials used in the detector must exhibit low levels of radioactive contamination. The single-event rate in the fiducial volume (R < 17.2 m) of the scintillator is required to be approximately 7 Hz for energies above 0.7 MeV, resulting in an accidental coincidence background of about 1 event per day for reactor neutrino physics analyses. Since the beginning of the construction phase, we have screened the natural radioactivity content of thousands of materials to select those that satisfy the design background budget. The concentrations of radioactive impurities in the materials ultimately used in the JUNO detector are summarized in this paper. Construction of the entire detector and subsequent filling with liquid scintillator were completed in August 2025. Initial data indicate that the total count rate from natural radioactivity within the detector's fiducial volume has reached nearly 5 Hz, with a 20–30% uncertainty arising from differences among reconstruction algorithms. This background level is sufficient to support the reactor antineutrino analysis.