Transverse Phase Space Measurement Based on Computerized Tomography

  • Precise measurements of emittance and transverse phase space are essential to generation and applications of high brightness electron beams. Compared to the quadrupole-scanning technique which treats the phase space distributions as ellipses and only measure the sigma matrices that define the ellipses, the measurement of transverse phase space based on CT(computerized tomography) measures the actual phase space distributions while making no a priori assumptions about the distributions. This process is capable of reconstructing transverse phase space distributions that are not elliptical. The theories of CT based measurements are studied. The preliminary experiment result is presented which is in good agreement with that obtained from quadruple scanning.
  • 加载中
  • [1] . Carlsten B E. Nucl. Instr. Methods Phys. Res., Sect. 1989,A285: 313-3192. QIU X, Batchelor K, Ben-Zvi I et al. Physical Review Let-ters, 1996, 76(20): 3723-37263. Yakimenko V, Babzien M, Ben-Zvi I et al. Physical ReviewSpecial Topic-Accelerators and Beams, 2003, 6: 1228014. Braun H, Chautard F, Corsini R et al. Physical ReviewLetters, 2000, 84(4): 658-6615. Anderson S G, Rosenweig J B, Musumeci P et al. PhysicalReview Letters, 2003, 91(7): 0478036. Gallardo Juan C, Robert B. Palmer. IEEE Journal ofQuantum Electronics, 1990, 26(8): 1328-13317. Hanerfeld H, Herrmannsfeldt W, Miller R H. SLAC-PUB-49168. Kak A C, Sianey M. Principles of Computerized Tomo-graphic Imaging. Electronic Copy, 19999. YU Neng-Jie, TANG Chuan-Xiang, ZHENG Shu-Xin et al.HEP NP, 2005, 29(4): 408-412(in Chinese)(俞能杰,唐传祥,郑曙新等.高能物理与核物理,2005,29(4):408—412)10. McKee C B, O'Shea P G, Madey J M. J Nucl. Instr. Methods. in Phys Res., 1995, A358: 264-26711. SHI Yi-Jin. High Power Laser and Particle Beams, 2000,12(2): 231-234(in Chinese)(施义晋.强激光与粒子束,2000, 12(2): 231-234)12. GU An-Jia, DING Yuan-Tao, ZHAO Kui et al. HEP NP,2003, 27(5): 455-459(in Chinese)(谷安佳,丁源涛,赵夔等.高能物理与核物理,2003, 27(5):455-459)
  • 加载中

Get Citation
DU Ying-Chao, XIANG Dao, HUANG Wen-Hui, HE Xiao-Zhong, CHENG Cheng, DU Tai-Bin, TANG Chuan-Xiang and LIN Yu-Zheng. Transverse Phase Space Measurement Based on Computerized Tomography[J]. Chinese Physics C, 2006, 30(9): 888-891.
DU Ying-Chao, XIANG Dao, HUANG Wen-Hui, HE Xiao-Zhong, CHENG Cheng, DU Tai-Bin, TANG Chuan-Xiang and LIN Yu-Zheng. Transverse Phase Space Measurement Based on Computerized Tomography[J]. Chinese Physics C, 2006, 30(9): 888-891. shu
Milestone
Received: 2005-11-16
Revised: 2006-01-20
Article Metric

Article Views(3241)
PDF Downloads(680)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Transverse Phase Space Measurement Based on Computerized Tomography

    Corresponding author: DU Ying-Chao,
  • Department of Engineering Physics, Tsinghua University, Beijing 100084, China

Abstract: Precise measurements of emittance and transverse phase space are essential to generation and applications of high brightness electron beams. Compared to the quadrupole-scanning technique which treats the phase space distributions as ellipses and only measure the sigma matrices that define the ellipses, the measurement of transverse phase space based on CT(computerized tomography) measures the actual phase space distributions while making no a priori assumptions about the distributions. This process is capable of reconstructing transverse phase space distributions that are not elliptical. The theories of CT based measurements are studied. The preliminary experiment result is presented which is in good agreement with that obtained from quadruple scanning.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return