Compact, Low-cost, 14.5 GHz All-permanent Magnet Field ECR Ion Source

Get Citation
E.Galutschek1, E.Salzborn2, F.Aumayr1 and HP.Winter1. Compact, Low-cost, 14.5 GHz All-permanent Magnet Field ECR Ion Source[J]. Chinese Physics C, 2007, 31(S1): 66-69.
E.Galutschek1, E.Salzborn2, F.Aumayr1 and HP.Winter1. Compact, Low-cost, 14.5 GHz All-permanent Magnet Field ECR Ion Source[J]. Chinese Physics C, 2007, 31(S1): 66-69. shu
Milestone
Received: 2007-05-30
Revised: 1900-01-01
Article Metric

Article Views(2951)
PDF Downloads(778)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Compact, Low-cost, 14.5 GHz All-permanent Magnet Field ECR Ion Source

  • Institut fur Allgemeine Physik, Vienna University of Technology, Vienna 1040, Austria2 Institut fur Atom- und Molekulphysik, Justus-Liebig University, Giessen 35390, Germany

Abstract: A compact 14.5GHz electron cyclotron resonance (ECR) ion source for the production of slow, multiply charged ions has been constructed, with the plasma-confining magnetic field produced exclusively by permanent magnets. Microwave power of up to 175W in the frequency range from 12.75 to 14.5GHz is transmitted from ground potential via a PTFE window into the water-cooled plasma chamber which can be equipped with an aluminum liner. The waveguide coupling system serves also as biased electrode, and two remotely-controlled gas inlet valves connected via an insulating break permit plasma operation in the gas-mixing mode. A triode extraction system sustains ion acceleration voltages between 1kV and 10kV. The ECR ion source is fully computer-controlled and can be remotely operated from any desired location via Ethernet.

    HTML

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return