×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Research on Measurement of 182Hf with HI-13 AMS System

Get Citation
QIU Jiu-Zi, JIANG Shan, HE Ming, YIN Xin-Yi, DONG Ke-Jun, GUAN Yong-Jing and WU Shao-Yong. Research on Measurement of 182Hf with HI-13 AMS System[J]. Chinese Physics C, 2007, 31(8): 719-723.
QIU Jiu-Zi, JIANG Shan, HE Ming, YIN Xin-Yi, DONG Ke-Jun, GUAN Yong-Jing and WU Shao-Yong. Research on Measurement of 182Hf with HI-13 AMS System[J]. Chinese Physics C, 2007, 31(8): 719-723. shu
Milestone
Received: 2006-10-08
Revised: 2006-11-15
Article Metric

Article Views(1642)
PDF Downloads(666)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Research on Measurement of 182Hf with HI-13 AMS System

    Corresponding author: QIU Jiu-Zi,
  • Chinese People's Armed Police Force Academy, Langfang 065000, China2 Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, China3 Department of Physics, Guangxi University, Nanning 530000, China

Abstract: 182Hf with half-life of about (8.90±0.09) Ma is an extinct radionuclide and can only be produced by a supernova explosion in nature. Therefore 182Hf is an ideal candidate nuclide for the study on possible supernova explosions in the vicinity of the earth within the last 100 million years. In addition, 182Hf is a long-lived radionuclide of particular interest for nuclear engineering. Accurate measurement of ultra-trace 182Hf is very important for reactor design,studies on nuclear cosmo-physics and other fields. With an accelerator mass spectrometry (AMS), it is possible to detect the trace amounts of 182Hf. In this paper, the detection method of 182Hf with HI-13 AMS system at China Institute of Atomic Energy (CIAE) and the chemical procedures to reduce 182W interference are presented. The energy and TOF two-dimension spectra of 182Hf and 183W for blank and a series of standard samples have been obtained, respectively. The 182W contribution to the counts in 182Hf peak was corrected by 183W normalization. The detection sensitivity of this AMS facility for 182Hf/180Hf ratio measurement is about 4.15±10-11 at present.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return