Energy Calibration of CsI(Tl) Crystal for Quenching Factor Measurement in Dark Matter Search

Get Citation
YUE Qian, LIU Yan, LI Jin, WANG H and WANG M. Energy Calibration of CsI(Tl) Crystal for Quenching Factor Measurement in Dark Matter Search[J]. Chinese Physics C, 2002, 26(7): 728-734.
YUE Qian, LIU Yan, LI Jin, WANG H and WANG M. Energy Calibration of CsI(Tl) Crystal for Quenching Factor Measurement in Dark Matter Search[J]. Chinese Physics C, 2002, 26(7): 728-734. shu
Milestone
Received: 2001-08-13
Revised: 1900-01-01
Article Metric

Article Views(2755)
PDF Downloads(567)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Energy Calibration of CsI(Tl) Crystal for Quenching Factor Measurement in Dark Matter Search

    Corresponding author: YUE Qian,
  • Institute of High Energy Physics, Chinese Academy of Science, Beijing 1000392 Institute of Physics, Academia Sinica, Taipei 115293 Department of Physics, Taiwan University, Taipei 10600

Abstract: It is important to measure the quenching factor of recoiled nuclei of detector for direct detection of WIMP. Energy calibration of CsI(Tl) crystal detector for measuring quenching factor of recoiled nuclei induced by incident neutron beam has been done with low-energy X-ray sources such as 109Cd and 133Ba and the linearity of energy response of experimental system is obtained. The equivalent energy deposited in CsI(Tl) crystal of a single photoelectron of PMT has been measured. The time of integration of current signals is optimized for different X-ray source energys.