Effect of cavity length detuning on the output characteristics for the middle infrared FEL oscillator of FELiChEM

  • FELiChEM is an infrared free electron laser (FEL) facility currently under construction, which consists of two oscillators generating middle-infrared and far-infrared laser covering the spectral range of 2.5-200 μm. In this paper, we numerically study the output characteristics of the middle-infrared oscillator with accurate cavity length detuning. Emphasis is put on the temporal structure of the micropulse and the corresponding spectral bandwidth. Taking the radiation wavelengths of 50 μm and 5 μm as examples, we show that the output pulse duration can be tuned in the range of 1-6 ps with corresponding bandwidth of 13%-0.2% by adjusting the cavity length detuning. In addition, a special discussion on the comb structure is presented, and it is indicated that the comb structure may arise in the output optical pulse when the normalized slippage length is much smaller than unity. This work has reference value for the operation of FELiChEM and other FEL oscillators.
      PCAS:
  • 加载中
  • [1] P. Emma et al, Nat. Photon., 4:641(2010)
    [2] E. Allaria et al, J. Synchrotron Rad., 22:485(2015)
    [3] DENG Hai-Xiao et al, Chinese Physics C, 38:028101(2014)
    [4] J. M. Ortega, Nucl. Instrum. Methods A, 341:138(1994)
    [5] N. Vinokurov, J. of IRMMTHz Waves, 32:1123(2011)
    [6] L. Giannessi et al, Phys. Rev. Lett., 106.14:144801(2011)
    [7] Z. T. Zhao et al, Nature Photonics, 6 (6):360-363(2012)
    [8] J. M. Ortega, M. Bergher, R. Chaput et al, Nucl. Instrum. Methods A, 285:97-103(1989)
    [9] W. Schollkopf et al, First lasing of the IR FEL at the FritzHaber Institut, Berlin. Proc. of FEL Conference. Nara, Japan. 2012, p. 1-4
    [10] W. Schollkopf et al, The new IR and THz FEL Facility at the Fritz Haber Institute in Berlin. Proc. of SPIE, 9512:95121L-1(2015)
    [11] P. W. van Amersfoort, R. W. B. Best, R. van Buuren et al, Nucl. Instrum. Methods A, 296:217-221(1990)
    [12] P. W. van Amersfoort, R. J. Bakker, J. B. Bekkers et al, Nucl. Instrum. Methods A, 318:42-46(1992)
    [13] Heting Li, Yalin Lu, Zhigang He, Qika Jia, and Lin Wang, J. of IRMMTHz Waves, 37:649-657(2016)
    [14] Y.-C. Huang, Appl. Phys. Lett., 96:2315039(2010)
    [15] He-Ting Li, Qi-Ka Jia, Shan-Cai Zhang, Lin Wang, and Yong-Liang Yang, Chinese Physics C, 41:018102(2017)
    [16] Kim, Kwang-Je, Phys. Rev. Lett., 66:2746(1991)
    [17] N. Piovella et al, Physical Review E, 52 (5):5470(1995)
    [18] G. Dattoli et al, IEEE J. Quantum Electron, 17:1371(1981)
    [19] G. Dattoli et al, Journal of Applied Physics, 101:103109(2007)
    [20] P. L. Ottaviani et al, Nucl. Instrum. Methods A, 834:108-117(2016)
    [21] R. Bonifacio et al, J. of IRMMTHz Waves, 28 (9):699-704(2007)
    [22] S. Reiche, Nucl. Instrum. Methods A, 429:243(1999)
    [23] Vander slot P et al, Phys. Rev. Lett., 102:244802(2009)
    [24] W. B. Colson, Nucl. Instrum. Methods A, 250:168-175(1986)
    [25] B. A. Richman, J. M. J. Madey, E. Szamers, Phys. Rev. Lett., 16:1682(1989)
    [26] G. M. H. Knippels et al, Phys. Rev. Lett., 75:1755(1995)
  • 加载中

Get Citation
Zhou-Yu Zhao, He-Ting Li and Qi-Ka Jia. Effect of cavity length detuning on the output characteristics for the middle infrared FEL oscillator of FELiChEM[J]. Chinese Physics C, 2017, 41(10): 108101. doi: 10.1088/1674-1137/41/10/108101
Zhou-Yu Zhao, He-Ting Li and Qi-Ka Jia. Effect of cavity length detuning on the output characteristics for the middle infrared FEL oscillator of FELiChEM[J]. Chinese Physics C, 2017, 41(10): 108101.  doi: 10.1088/1674-1137/41/10/108101 shu
Milestone
Received: 2017-04-06
Revised: 2017-07-05
Fund

    Supported by National Natural Science Foundation of China (21327901, 11205156)

Article Metric

Article Views(1336)
PDF Downloads(37)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Effect of cavity length detuning on the output characteristics for the middle infrared FEL oscillator of FELiChEM

    Corresponding author: He-Ting Li,
  • 1. National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
Fund Project:  Supported by National Natural Science Foundation of China (21327901, 11205156)

Abstract: FELiChEM is an infrared free electron laser (FEL) facility currently under construction, which consists of two oscillators generating middle-infrared and far-infrared laser covering the spectral range of 2.5-200 μm. In this paper, we numerically study the output characteristics of the middle-infrared oscillator with accurate cavity length detuning. Emphasis is put on the temporal structure of the micropulse and the corresponding spectral bandwidth. Taking the radiation wavelengths of 50 μm and 5 μm as examples, we show that the output pulse duration can be tuned in the range of 1-6 ps with corresponding bandwidth of 13%-0.2% by adjusting the cavity length detuning. In addition, a special discussion on the comb structure is presented, and it is indicated that the comb structure may arise in the output optical pulse when the normalized slippage length is much smaller than unity. This work has reference value for the operation of FELiChEM and other FEL oscillators.

    HTML

Reference (26)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return