×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Central RF frequency measurement of the HLS-Ⅱ storage ring

Get Citation
Jia-Jun Zheng, Yong-Liang Yang, Bao-Gen Sun, Fang-Fang Wu, Chao-Cai Cheng, Kai Tang and Jun-Hao Wei. Central RF frequency measurement of the HLS-Ⅱ storage ring[J]. Chinese Physics C, 2016, 40(4): 047005. doi: 10.1088/1674-1137/40/4/047005
Jia-Jun Zheng, Yong-Liang Yang, Bao-Gen Sun, Fang-Fang Wu, Chao-Cai Cheng, Kai Tang and Jun-Hao Wei. Central RF frequency measurement of the HLS-Ⅱ storage ring[J]. Chinese Physics C, 2016, 40(4): 047005.  doi: 10.1088/1674-1137/40/4/047005 shu
Milestone
Received: 2015-08-14
Fund

    Supported by National Natural Science Foundation of China(11105141, 11175173) and the upgrade project of Hefei Light Source

Article Metric

Article Views(1546)
PDF Downloads(106)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Central RF frequency measurement of the HLS-Ⅱ storage ring

    Corresponding author: Jia-Jun Zheng,
    Corresponding author: Yong-Liang Yang,
  • 1. National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
Fund Project:  Supported by National Natural Science Foundation of China(11105141, 11175173) and the upgrade project of Hefei Light Source

Abstract: Central RF frequency is a key parameter of storage rings. This paper presents the measurement of central RF frequency of the HLS-Ⅱ storage ring with the sextupole modulation method. Firstly, the basis of central RF frequency measurement of the electron storage ring is briefly introduced. Then, the error sources and the optimized measurement method for the HLS-Ⅱ storage ring are discussed. The workflow of a self-compiled Matlab script used in central RF frequency measurement is also described. Finally, the results achieved by using two data processing methods to cross-check each other are shown. The measured value of the central RF frequency demonstrates that the circumference deviation of the HLS-Ⅱ storage ring is less than 1 mm.

    HTML

Reference (9)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return