×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

A cosmic ray test platform based on high time resolution MRPC technology

Get Citation
CHEN Tian-Xiang, LI Cheng, SUN Yong-Jie, CHEN Hong-Fang, SHAO Ming, TANG Ze-Bo, YANG Rong-Xing, ZHOU Yi and ZHANG Yi-Fei. A cosmic ray test platform based on high time resolution MRPC technology[J]. Chinese Physics C, 2015, 39(5): 056003. doi: 10.1088/1674-1137/39/5/056003
CHEN Tian-Xiang, LI Cheng, SUN Yong-Jie, CHEN Hong-Fang, SHAO Ming, TANG Ze-Bo, YANG Rong-Xing, ZHOU Yi and ZHANG Yi-Fei. A cosmic ray test platform based on high time resolution MRPC technology[J]. Chinese Physics C, 2015, 39(5): 056003.  doi: 10.1088/1674-1137/39/5/056003 shu
Milestone
Received: 2014-08-26
Revised: 2014-11-08
Article Metric

Article Views(2256)
PDF Downloads(126)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

A cosmic ray test platform based on high time resolution MRPC technology

    Corresponding author: CHEN Tian-Xiang,
    Corresponding author: LI Cheng,

Abstract: In order to test the performance of detector prototypes in a laboratory environment, we design and build a large area (90 cm×52 cm) test platform for cosmic rays based on a well-designed Multi-gap Resistive Plate Chamber (MRPC) with excellent time resolution and a high detection efficiency for minimum ionizing particles. The time resolution of the MRPC module used is tested to be ~80 ps, and the position resolution along the strip is ~5 mm, while the position resolution perpendicular to the strip is ~12.7 mm. The platform constructed by four MRPC modules can be used for tracking cosmic rays with a spatial resolution of ~6.3 mm, and provide a reference time ~40 ps.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return