×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution

Get Citation
JIA Quan-Jie, CHEN Yu, LI Gang and JIANG Xiao-Ming. Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution[J]. Chinese Physics C, 2012, 36(3): 267-274. doi: 10.1088/1674-1137/36/3/014
JIA Quan-Jie, CHEN Yu, LI Gang and JIANG Xiao-Ming. Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution[J]. Chinese Physics C, 2012, 36(3): 267-274.  doi: 10.1088/1674-1137/36/3/014 shu
Milestone
Received: 2011-05-16
Revised: 2011-07-29
Article Metric

Article Views(2429)
PDF Downloads(377)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution

    Corresponding author: JIANG Xiao-Ming,

Abstract: Employing the approximation theory based on refraction and the definition of the total point-spread-function of the imaging system, the variation in the edge contrast of simple model samples is discussed with different source-to-sample and sample-to-detector distances, which actually means different spatial resolutions of the imaging system. The experiments were carried out with the Beamline 4W1A imaging setup at the Beijing Synchrotron Radiation Facility for simple model and insect samples. The results show that to obtain clear phase-contrast images of biologic tissues for the X-ray in-line imaging setup, with determined parameters such as the size of the X-ray source, the pixel size of the detector and the fixed source-to-sample distance, there is a range of optimized sample-to-detector distances. The analysis method discussed in this article can be helpful in optimizing the setup of X-ray in-line phase-contrast imaging.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return