Courant-Snyder invariant density screening method for emittance analysis

  • Emittance is an important characteristic of describing charged particle beams. In hadron accelerators, we often meet irregular beam distributions that are not appropriately described by a single rms emittance or 95% emittance or total emittance. In this paper,it is pointed out that in many cases a beam halo should be described with very different Courant-Snyder parameters from the ones used for the beam core. A new method — the Courant-Snyder invariant density screening method - is introduced for analyzing emittance data clearly and accurately. The method treats the emittance data from both measurements and numerical simulations. The method uses the statistical distribution of the beam around each particle in phase space to mark its local density parameter, and then uses the density distribution to calculate the beam parameters such as the Courant-Snyder parameters and emittance for different beam boundary definitions. The method has been used in the calculations for beams from different sources, and shows its advantages over other methods. An application code based on the method including the graphic interface has also been designed.
      PCAS:
  • 加载中
  • [1] Buon J. Beam Phase Space and Emittance, CERN Accelerator School, 4th general course, 91-04, 302 Frank J. Sacherer, RMS Envelope Equations with Space Charge, PAC1971, CERN, Geneva, Switzerland, 1105-11073 Takeda H. Parmila, LA-UR-98-4478, Los Alamos National Laboratory, 2005, 47-494 Crandall K R, Rusthoi D P. TRACE 3-D Documentation (Third Edition), LA-UR-97-886, Los Alamos National Laboratory, 1997. 3, 705 Galambos J D, Holmes J A, Olsen D K. ORBIT User Manual Version 1.10, SNS Building MS-8218, Oak Ridge National Laboratory, 1999, 15-166 TANG Jing-Yu. Nucl. Instrum. Methods A, 2008, 595: 561-5677 Stockli M P, Welton R F, Keller R. Self-consistent, Unbiased Exclusion Methods of Emittance Analysis, 20th IEEE Particle Accelerator Conference, Portland, OR, USA, 2003, 5278 Stockli M P. AIP Conf. Proc., 2006, 868: 25-629 Stockli M P et al. AIP Conf. Proc., 2002, 639: 135-15910 WEI Jie et al. Nuc. Inst. Meth. Phys. Res. A, 2009, 600: 10-1311 Private communication with MENG Cai12 Private communication with Peng Jun13 The Mathworks Inc., Matlab trial software
  • 加载中

Get Citation
SUN Ji-Lei, TANG Jing-Yu and JING Han-Tao. Courant-Snyder invariant density screening method for emittance analysis[J]. Chinese Physics C, 2011, 35(11): 1059-1065. doi: 10.1088/1674-1137/35/11/015
SUN Ji-Lei, TANG Jing-Yu and JING Han-Tao. Courant-Snyder invariant density screening method for emittance analysis[J]. Chinese Physics C, 2011, 35(11): 1059-1065.  doi: 10.1088/1674-1137/35/11/015 shu
Milestone
Received: 2011-03-10
Revised: 2011-04-07
Article Metric

Article Views(2408)
PDF Downloads(349)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Courant-Snyder invariant density screening method for emittance analysis

Abstract: Emittance is an important characteristic of describing charged particle beams. In hadron accelerators, we often meet irregular beam distributions that are not appropriately described by a single rms emittance or 95% emittance or total emittance. In this paper,it is pointed out that in many cases a beam halo should be described with very different Courant-Snyder parameters from the ones used for the beam core. A new method — the Courant-Snyder invariant density screening method - is introduced for analyzing emittance data clearly and accurately. The method treats the emittance data from both measurements and numerical simulations. The method uses the statistical distribution of the beam around each particle in phase space to mark its local density parameter, and then uses the density distribution to calculate the beam parameters such as the Courant-Snyder parameters and emittance for different beam boundary definitions. The method has been used in the calculations for beams from different sources, and shows its advantages over other methods. An application code based on the method including the graphic interface has also been designed.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return